ArticleJournal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance2008
Combined myocardial stress perfusion imaging and myocardial stress tagging for detection of coronary artery disease at 3 Tesla.
Article in Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance, 2008. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
8 citing papers in PubMed, 1 synthesis or guideline pooled it, 22 citations in OpenAlex.
- Meta-analysis of the diagnostic performance of stress perfusion cardiovascular magnetic resonance for detection of coronary artery disease.Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance · 2010Pooled it
- Clinical value of hyperemic left ventricular systolic function in vasodilator stress testing.Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2017Review
- Cardiac Imaging in Heart Failure with Comorbidities.Current cardiology reviews · 2017Review
- The effect of high-permittivity pads on specific absorption rate in radiofrequency-shimmed dual-transmit cardiovascular magnetic resonance at 3T.Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance · 2015Article
- Identification of left ventricular myocardial ischemia and cardiac prognosis with cardiovascular magnetic resonance: updates from 2008 to 2010.Current cardiology reports · 2011Review
- Review of Journal of Cardiovascular Magnetic Resonance 2009.Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance · 2010Review
- Cardiac magnetic resonance imaging for the diagnosis of coronary artery disease: an evidence-based analysis.Ontario health technology assessment series · 2010Article
- Assessment of myocardial ischemia with cardiovascular magnetic resonance.Progress in cardiovascular diseasesReview
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundAdenosine stress perfusion is very sensitive for detection of coronary artery disease (CAD), and yields good specificity. Standard adenosine cine imaging lacks high sensitivity, but is very specific. Myocardial tagging improves detection of wall motion abnormalities (WMAs). Perfusion and tagging cardiovascular magnetic resonance (CMR) both benefit from high field imaging (improved contrast to noise ratio and tag persistence). We investigated the diagnostic impact of a combined stress perfusion-tagging protocol for detection of CAD at 3 Tesla.
methodsStress perfusion and tagging images were acquired in 3 identical short axis locations (slice thickness 8 mm, FOV 320-380 mm, matrix 256(2)). A positive finding at coronary angiography was defined as stenosis or flow limiting restenosis > 50% in native and graft vessels. A true positive CMR - finding was defined as > or = 1 perfusion deficit or new WMA during adenosine-stress in angiographically corresponding regions.
resultsWe included 60 patients (males: 41, females: 19; 21 suspected, 39 known CAD). Myocardial tagging extended stress imaging by 1.5-3 min and was well tolerated by all patients. Sensitivity and specificity for detection of significant CAD by adenosine stress perfusion were 0.93 and 0.84, respectively. The sensitivity of adenosine stress tagging was less (0.64), while the specificity was very high (1.0). The combination of both stress perfusion and stress tagging did not increase sensitivity.
conclusionThe combined adenosine stress perfusion-tagging protocol delivers high sensitivity and specificity for detection of significant CAD. While the sensitivity of adenosine stress tagging is poor compared to perfusion imaging, its specificity is very high. This technique should thus prove useful in cases of inconclusive perfusion studies to help avoid false positive results.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.