ArticleJournal of fluorescence2009
Simultaneous determination of glucose and choline based on the intrinsic fluorescence of the enzymes.
Article in Journal of fluorescence, 2009. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed, 7 citations in OpenAlex.
- Binding of quercetin to lysozyme as probed by spectroscopic analysis and molecular simulation.Journal of fluorescence · 2011Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
It has been possible to perform the simultaneous determination of choline and glucose using the intrinsic fluorescence of the corresponding enzyme as an analytical signal. This can be done in two ways. First, for low glucose and choline concentrations (about 0.55 mM and 0.75 microM respectively) two differentiated signals, without mutual interference, are obtained for both analytes in the same measurement. Second, when glucose and choline concentrations are higher, a new model has been designed which permits the concentrations to be accurately determined in samples containing from 0.55 mM to 3.75 mM glucose and from 0.75 microM to 11.0 microM choline; the method has been applied to simultaneous glucose and choline determinations in serum samples with good results. This method gives a better performance than multivariate calibration based on Partial Least Squares Regression. The methodology here shown could be also used for the simultaneous determination of other pairs of analytes.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.