Evidence map›Paper›PMID 18989667›Full record

ArticleEuropean journal of nuclear medicine and molecular imaging2009

Standardization of the heart-to-mediastinum ratio of 123I-labelled-metaiodobenzylguanidine uptake using the dual energy window method: feasibility of correction with different camera-collimator combinations.

Shinro Matsuo, Kenichi Nakajima, Koichi Okuda, Masaya Kawano, Takehiro Ishikawa, Tetsuo Hosoya, Junichi Taki, Seigo Kinuya

Open access · greenAbstract read
PubMed Publisher
In one paragraph

Article in European journal of nuclear medicine and molecular imaging, 2009. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 15 papers.

0numbers the graph read from it
0cells of the map it votes in
15citing papers in PubMed
2.7field-weighted citation impact, top 11% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

15 citing papers in PubMed, 32 citations in OpenAlex.

  1. Trial
  2. An improved method for estimating the heart-to-mediastinum ratio from cardiac sympathetic nerve imaging with low-energy high-resolution collimators.Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2014
    Trial
  3. Article
  4. Article
  5. Article
  6. Influence of ROI definition on the heart-to-mediastinum ratio in planarJournal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2018
    Article
  7. ASNC imaging guidelines for SPECT nuclear cardiology procedures: Stress, protocols, and tracers.Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2016
    Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Semi-automated algorithm for calculating heart-to-mediastinum ratio in cardiac Iodine-123 MIBG imaging.Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2011
    Article
  14. Article
  15. Review
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

8 authors at 3 institutions in 1 country.

Shinro MatsuoDepartment of Nuclear Medicine, Kanazawa University Hospital, Kanazawa 920-8641, Japan. smatsuo@nmd.m.kanazawa-u.ac.jp
Kenichi Nakajima
Koichi Okuda
Masaya Kawano
Takehiro Ishikawa
Tetsuo Hosoya
Junichi Taki
Seigo Kinuya
Kanazawa University Hospital · JPFujifilm (Japan) · JPKanazawa University · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundAlthough the heart-to-mediastinum (H/M) ratio in a planar image has been used for practical quantification in (123)I-metaiodobenzylguanidine (MIBG) imaging, standardization of the parameter is not yet established. We hypothesized that the value of the H/M ratio could be standardized to the various camera-collimator combinations. METHODS AND

resultsStandard phantoms consisting of the heart and mediastinum were made. A low-energy high-resolution (LEHR) collimator and a medium-energy (ME) collimator were used. We examined multi-window correction methods with (123)I- dual-window (IDW) acquisition, and planar images were obtained with IDW correction and the LEHR collimator. The images were obtained using the following gamma camera systems: GCA 9300A (Toshiba, Tokyo), E.CAM Signature (Toshiba/Siemens, Tokyo) and Varicam (GE, Tokyo). Cardiac phantom studies demonstrated that contamination of the H/M count ratio was greater with the LEHR collimator and least with the ME collimator. The corrected H/M ratio with the LEHR collimator was similar to that with ME collimators. The uncorrected H/M ratio with the ME collimator was linearly related to the H/M ratio with IDW correction with the LEHR collimator. The relationship between the uncorrected H/M ratios determined with the LEHR (E.CAM) and the ME collimators was y = 0.56x + 0.49, where y = H/M ratio with the E.CAM and x = H/M ratio with the ME collimator. The average normal values for the low-energy collimator (n=18) were 2.2+/-0.2 (initial H/M ratio) and 2.42+/-0.2 (delayed H/M ratio), and for the low/medium-energy (LME) collimator (n=14) were 2.63+/-0.25 (initial H/M ratio) and 2.87+/-0.19 (delayed H/M ratio). H/M ratios in previous clinical studies using LEHR collimators are comparable to those with ME collimators.

conclusionThe IDW-corrected H/M ratios determined with the LEHR collimator were similar to those determined with the ME collimator. This finding could make it possible to standardize the H/M ratio in planar imaging among various collimators in the clinical setting.

Indexed as

3-IodobenzylguanidineAutomationCardiologyDiagnostic ImagingEquipment DesignHeartImage Interpretation, Computer-AssistedIodine RadioisotopesMediastinumModels, TheoreticalPhantoms, ImagingRadionuclide ImagingRadiopharmaceuticalsScattering, Radiation3-IodobenzylguanidineIodine RadioisotopesRadiopharmaceuticals

Identifiers

PMID18989667
OpenAlexW2052424462

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.