ArticleIntensive care medicine2009
Adult ICU ventilators to provide neonatal ventilation: a lung simulator study.
Article in Intensive care medicine, 2009. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
8 citing papers in PubMed, 30 citations in OpenAlex.
- The in-vitro performance of a modern portable respirator in different lung models and as an alternative intensive care respirator: A simulation based cohort study.European journal of anaesthesiology and intensive care · 2025Article
- Additional work of breathing from trigger errors in mechanically ventilated children.Respiratory research · 2020Observational
- The Difference Between Set and Delivered Tidal Volume: A Lung Simulation Study.Medical devices (Auckland, N.Z.) · 2020Article
- [Monitoring tidal volumes when using the Ventrain® emergency ventilator].Der Anaesthesist · 2016Article
- Healthcare Technology Management (HTM) of mechanical ventilators by clinical engineers.Journal of intensive care · 2014Article
- Simulations for mechanical ventilation in children: review and future prospects.Critical care research and practice · 2013Article
- ICU mechanical ventilators, technological advances vs. user friendliness: the right picture is worth a thousand numbers.Intensive care medicine · 2009Article
- Comment on "Adult ICU ventilators to provide neonatal ventilation: a lung simulator study".Intensive care medicine · 2009Article
Corrections and comments
- Commented on by
Authors and funding
4 authors at 3 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundTraditionally, specific ventilators have been manufactured to only provide neonatal mechanical ventilation. However, many of the current generation of ICU ventilators also include a neonatal mode.
methodsUsing the IngMar ASL5000 lung simulator the Puritan Bennett 840, the Maquet Servo i, the Viasys AVEA, the GE Engström, the Drager Evita XL and Babylog 8000 Plus were evaluated during assisted ventilation in the pressure assist/control mode. Three lung mechanics were set: resistance 50 cmH(2)O/L/s, compliance 2 mL/cmH(2)O; resistance 100 cmH(2)O/L/s, compliance 1 mL/cmH(2)O; and resistance 150 cmH(2)O/L/s, compliance 0.5 mL/cmH(2)O. A maximum negative pressure drop of 4 and 7 cmH(2)O was achieved during simulated inspirations. Each ventilator was evaluated with PEEP 5 cmH(2)O, peak pressure 20 cmH(2)O and inspiratory time 0.3 s and with PEEP 10 cmH(2)O, peak pressure 30 cmH(2)O and inspiratory time 0.4 s. Each ventilator setting was then repeated with a leak of 0.3 L/min at a constant pressure of 5 cmH(2)O.
resultsOverall each of the 5 ICU ventilators responded faster or greater than the Babylog with respect to: pressure to trigger (except the Servo i), time to trigger (except the Evita XL), time between trigger and return of pressure to baseline, time from start of breath to 90% of peak pressure (except the Avea) and pressure time product of breath activation. Expiratory tidal volume was also greater with all ICU ventilators except the Avea. Variation in mechanics, leak, PEEP and muscular effort had little effect on these differences.
conclusionAll ICU ventilators tested were able to at least equal the performance of the Babylog 8000 Plus on all variables evaluated.