ArticlePhysical review. E, Statistical, nonlinear, and soft matter physics2008
Finite-sized gas bubble motion in a blood vessel: non-Newtonian effects.
Article in Physical review. E, Statistical, nonlinear, and soft matter physics, 2008. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
9 citing papers in PubMed.
- Circulating Bubbles in Decompression Sickness: Pathophysiology and Experimental Models.Biomolecules · 2026Review
- Iatrogenic air embolism: pathoanatomy, thromboinflammation, endotheliopathy, and therapies.Frontiers in immunology · 2023Review
- Nanocarrier Hydrodynamics and Binding in Targeted Drug Delivery: Challenges in Numerical Modeling and Experimental Validation.Journal of nanotechnology in engineering and medicine · 2013Review
- Computational simulation of hematocrit effects on arterial gas embolism dynamics.Aviation, space, and environmental medicine · 2012Article
- Mechanotransductional basis of endothelial cell response to intravascular bubbles.Integrative biology : quantitative biosciences from nano to macro · 2011Article
- Nanoparticle Brownian motion and hydrodynamic interactions in the presence of flow fields.Physics of fluids (Woodbury, N.Y. : 1994) · 2011Article
- Surfactant properties differentially influence intravascular gas embolism mechanics.Annals of biomedical engineering · 2010Article
- Effect of a soluble surfactant on a finite sized bubble motion in a blood vessel.Journal of fluid mechanics · 2010Article
- In vitro surfactant mitigation of gas bubble contact-induced endothelial cell death.Undersea & hyperbaric medicine : journal of the Undersea and Hyperbaric Medical Society, IncArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
Abstract
We have numerically investigated the axisymmetric motion of a finite-sized nearly occluding air bubble through a shear-thinning Casson fluid flowing in blood vessels of circular cross section. The numerical solution entails solving a two-layer fluid model--a cell-free layer and a non-Newtonian core together with the gas bubble. This problem is of interest to the field of rheology and for gas embolism studies in health sciences. The numerical method is based on a modified front-tracking method. The viscosity expression in the Casson model for blood (bulk fluid) includes the hematocrit [the volume fraction of red blood cells (RBCs)] as an explicit parameter. Three different flow Reynolds numbers, Reapp=rholUmaxdmicroapp , in the neighborhood of 0.2, 2, and 200 are investigated. Here, rhol is the density of blood, Umax is the centerline velocity of the inlet Casson profile, d is the diameter of the vessel, and microapp is the apparent viscosity of whole blood. Three different hematocrits have also been considered: 0.45, 0.4, and 0.335. The vessel sizes considered correspond to small arteries, and small and large arterioles in normal humans. The degree of bubble occlusion is characterized by the ratio of bubble to vessel radius (aspect ratio), lambda , in the range 0.9< or =lambda< or =1.05 . For arteriolar flow, where relevant, the Fahraeus-Lindqvist effects are taken into account. Both horizontal and vertical vessel geometries have been investigated. Many significant insights are revealed by our study: (i) bubble motion causes large temporal and spatial gradients of shear stress at the "endothelial cell" (EC) surface lining the blood vessel wall as the bubble approaches the cell, moves over it, and passes it by; (ii) rapid reversals occur in the sign of the shear stress (+ --> - --> +) imparted to the cell surface during bubble motion; (iii) large shear stress gradients together with sign reversals are ascribable to the development of a recirculation vortex at the rear of the bubble; (iv) computed magnitudes of shear stress gradients coupled with their sign reversals may correspond to levels that cause injury to the cell by membrane disruption through impulsive compression and stretching; and (v) for the vessel sizes and flow rates investigated, gravitational effects are negligible.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.