Evidence map›Paper›PMID 18698799›Full record

ArticleAnalytical chemistry2008

Contribution of aquaporins to cellular water transport observed by a microfluidic cell volume sensor.

Jinseok Heo, Fanjie Meng, Susan Z Hua

Open access · greenAbstract read
In one paragraph

Article in Analytical chemistry, 2008. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed
1.1field-weighted citation impact, top 24% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed, 36 citations in OpenAlex.

  1. Article
  2. Review
  3. Article
  4. Methods to Measure Water Permeability.Advances in experimental medicine and biology · 2023
    Article
  5. Molecular mechanisms of brain water transport.Nature reviews. Neuroscience · 2021
    Review
  6. Article
  7. Weak protein-protein interactions in live cells are quantified by cell-volume modulation.Proceedings of the National Academy of Sciences of the United States of America · 2017
    Article
  8. Review
  9. Article
  10. Shear-induced volume decrease in MDCK cells.Cellular physiology and biochemistry : international journal of experimental cellular physiology, biochemistry, and pharmacology · 2012
    Article
  11. Monitoring single-channel water permeability in polarized cells.The Journal of biological chemistry · 2011
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 1 institution in 1 country.

Jinseok HeoDepartment of Mechanical & Aerospace Engineering, SUNY-Buffalo, Buffalo, New York 14260, USA.
Fanjie Meng
Susan Z Hua
University at Buffalo, State University of New York · US

Funding

Time resolved studies of transport in renal epithelial cellsK25DK077302 · NIDDK · STATE UNIVERSITY OF NEW YORK AT BUFFALO · PI HUA, ZONGLU S · 2007 to 2011
$939k
NIDDK NIH HHS DK77302NIDDK NIH HHS K25 DK077302
6 · The paper itself

Abstract

Here we demonstrate that an impedance-based microfluidic cell volume sensor can be used to study the roles of aquaporin (AQP) in cellular water permeability and screen AQP-specific drugs. Human embryonic kidney (HEK-293) cells were transiently transfected with AQP3- or AQP4-encoding genes to express AQPs in plasma membranes. The swelling of cells in response to hypotonic stimulation was traced in real time using the sensor. Two time constants were obtained by fitting the swelling curves with a two-exponential function, a fast time constant associated with osmotic water permeability of AQP-expressing cells and a slow phase time constant associated mainly with water diffusion through lipid bilayers in the nontransfected cells. The AQP-expressing cells showed at least 10x faster osmotic water transport than control cells. Using the volume sensor, we examined the effects of Hg (2+) and Ni (2+) on the water transport via AQPs. Hg (2+) inhibited the water flux in AQP3-expressing cells irreversibly, while Ni (2+) blocked the AQP3 channels reversibly. Neither of the two ions blocked the AQP4 channels. The microfluidic volume sensor can sense changes in cell volume in real time, which enables perfusion of various reagents sequentially. It provides a convenient tool for studying the effect of reagents on the function and regulation mechanism of AQPs.

Indexed as

Cell SizeAquaporin 3Aquaporin 4AquaporinsCell LineCellsGene ExpressionHumansIndicators and ReagentsKineticsMetals, HeavyMicrofluidic Analytical TechniquesPermeabilitySubstrate SpecificityTransfectionWaterAquaporin 3Aquaporin 4AquaporinsIndicators and ReagentsMetals, HeavyWater

Identifiers

PMID18698799
PMCPMC2612540
OpenAlexW2011599666

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.