Evidence map›Paper›PMID 18596140›Full record

ArticleJournal of clinical microbiology2008

Performance of three commercial viral load assays, Versant human immunodeficiency virus type 1 (HIV-1) RNA bDNA v3.0, Cobas AmpliPrep/Cobas TaqMan HIV-1, and NucliSens HIV-1 EasyQ v1.2, testing HIV-1 non-B subtypes and recombinant variants.

Africa Holguín, Marisa López, Mar Molinero, Vincent Soriano

Abstract readComparative Study
In one paragraph

Article in Journal of clinical microbiology, 2008. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 18 papers.

0numbers the graph read from it
0cells of the map it votes in
18citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

18 citing papers in PubMed.

  1. Drug resistance in children and adolescents with HIV in Panama.The Journal of antimicrobial chemotherapy · 2023
    Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Article
  17. Article
  18. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Africa HolguínDepartment of Infectious Diseases, Hospital Carlos III, Madrid, Spain. aholguin.hciii@salud.madrid.org
Marisa López
Mar Molinero
Vincent Soriano

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Monitoring antiretroviral therapy requires that human immunodeficiency virus type 1 (HIV-1) viremia assays are applicable to all distinct variants. This study evaluates the performance of three commercial viral load assays-Versant HIV-1 RNA bDNA v3.0, Cobas AmpliPrep/Cobas TaqMan HIV-1, and NucliSens HIV-1 EasyQ v1.2-in testing 83 plasma specimens from patients carrying HIV-1 non-B subtypes and recombinants previously defined by phylogenetic analysis of the pol gene. All 28 specimens from patients under treatment presented viremia values below the detection limit with the three methods. In the remaining 55 specimens from naive individuals viremia could not be detected in 32.7, 20, and 14.6% using the NucliSens, Versant, or TaqMan tests, respectively, suggesting potential viral load underestimation of some samples by all techniques. Only 32 (58.2%) samples from naive subjects were quantified by the three methods; the NucliSens test provided the highest HIV RNA values (mean, 4.87 log copies/ml), and the Versant test provided the lowest (mean, 4.16 log copies/ml). Viremia differences of greater than 1 log were seen in 8 (14.5%) of 55 specimens, occurring in 10.9, 7.3, and 5.4%, respectively, of the specimens in comparisons of Versant versus NucliSens, Versant versus TaqMan, and TaqMan versus NucliSens. Differences greater than 0.5 log, considered significant for clinicians, occurred in 45.5, 27.3, and 29% when the same assays were compared. Some HIV-1 strains, such as subtype G and CRF02_AG, showed more discrepancies in distinct quantification methods than others. In summary, an adequate design of primers and probes is needed for optimal quantitation of plasma HIV-RNA in non-B subtypes. Our data emphasize the need to use the same method for monitoring patients on therapy and also the convenience of HIV-1 subtyping.

Indexed as

HIV-1Reagent Kits, DiagnosticViral LoadHIV InfectionsHumansSensitivity and SpecificityViremiaReagent Kits, Diagnostic

Identifiers

PMID18596140
PMCPMC2546710

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.