Evidence map›Paper›PMID 18559137›Full record

ArticleCardiology in the young2008

In situ fracture of stents implanted for relief of pulmonary arterial stenosis in patients with congenitally malformed hearts.

Doff B McElhinney, Lisa Bergersen, Audrey C Marshall

Abstract read
In one paragraph

Article in Cardiology in the young, 2008. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
1.4field-weighted citation impact, top 18% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed, 56 citations in OpenAlex.

  1. Article
  2. Review
  3. Article
  4. Article
  5. Article
  6. Pulmonary artery and lung parenchymal growth following early versus delayed stent interventions in a swine pulmonary artery stenosis model.Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2020
    Article
  7. Review
  8. Article
  9. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 2 institutions in 1 country.

Doff B McElhinneyDepartment of Cardiology, Children's Hospital, Boston, Massachusetts 02115, USA. doff.mcelhinney@cardio.chboston.org
Lisa Bergersen
Audrey C Marshall
Harvard University · USBoston Children's Hospital · US

Funding

RESEARCH METHODS IN PEDIATRICS HEART DISEASET32HL007572 · NHLBI · CHILDREN'S HOSPITAL BOSTON · PI Sarah D DE FERRANTI, Jane W. Newburger · 1985 to 2026
$13.0M
NHLBI NIH HHS T32 HL007572
6 · The paper itself

Abstract

backgroundOne of the most common uses of stents in patients with congenitally malformed hearts is treatment of pulmonary arterial stenosis. Although there are reports of fractured pulmonary arterial stents, little is known about the risk factors for, and implications of, such fractures.

methodsWe reviewed angiograms to identify fractures in stents previously inserted to relieve stenoses in pulmonary arteries from 1990 through 2001 in patients who also underwent follow-up catheterization at least 3 years after placement of the stent. We undertook matched cohort analysis, matching a ratio of 2 fractured to 1 unfractured stent.

resultsOverall, 166 stents meeting the criterions of our study had been placed in 120 patients. We identified fractures in 35 stents (21%) in 29 patients. All fractured stents were in the central pulmonary arteries, 24 (69%) in the central part of the right pulmonary artery, and all were complete axial fractures, or complex fractures along at least 2 planes. Stent-related factors associated with increased risk of fracture identified by multivariable logistic regression included placement in close apposition to the ascending aorta (p = 0.001), and a larger expanded diameter (p = 0.002). There was obstruction across 28 of 35 fractured stents, which was severe in 11. We re-stented 21 of the fractured stents, and recurrent fracture was later diagnosed in 3 of these. A fragment of the fractured stent embolized distally in 2 patients, without clinically important effects.

conclusionsIn situ fracture of pulmonary arterial stents is relatively common, and in most cases is related to compression by the aorta. There is usually recurrent obstruction across the fractured stent, but fractured stents rarely embolize, and are not associated with other significant complications.

Indexed as

Prosthesis FailureAdolescentAdultCardiac CatheterizationCase-Control StudiesChildChild, PreschoolConstriction, PathologicHeart Defects, CongenitalHumansInfantPulmonary ArteryRadiographyRisk FactorsStents

Identifiers

PMID18559137
PMCPMC4235280
OpenAlexW2118845238

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.