Trial reportCritical care (London, England)2008
Optic nerve sonography in the diagnostic evaluation of adult brain injury.
Trial report in Critical care (London, England), 2008. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT04603118 (Comparison of Optic Nerve Sheath Diameters Measured by Optic Ultrasonography Before and After Lumbar Puncture in Idiopathic Intracranial Hypertension Patients), which is not on this map. Cited by 126 papers, 3 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Comparison of Optic Nerve Sheath Diameters Measured by Optic Ultrasonography Before and After Lumbar Puncture in Idiopathic Intracranial Hypertension Patients
Who cites it
126 citing papers in PubMed, 3 syntheses or guidelines pooled it, 298 citations in OpenAlex.
- Prognostic Role of Optic Nerve Sheath Diameter for Neurological Outcomes in Post-Cardiac Arrest Patients: A Systematic Review and Meta-Analysis.BioMed research international · 2020Pooled it
- Diagnosis of elevated intracranial pressure in critically ill adults: systematic review and meta-analysis.BMJ (Clinical research ed.) · 2019Pooled it
- Ultrasonography of optic nerve sheath diameter for detection of raised intracranial pressure: a systematic review and meta-analysis.Intensive care medicine · 2011Pooled it
- Reverse Trendelenburg position applied prior to pneumoperitoneum prevents excessive increase in optic nerve sheath diameter in laparoscopic cholecystectomy: randomized controlled trial.Journal of clinical monitoring and computing · 2021Trial
- Correlation of optic nerve sheath diameter with directly measured intracranial pressure in Korean adults using bedside ultrasonography.PloS one · 2017Trial
- Impact of controlled intraabdominal pressure on the optic nerve sheath diameter during laparoscopic procedures.Surgical endoscopy · 2016Trial
- Transorbital sonographic evaluation of normal optic nerve sheath diameter in healthy volunteers in Bangladesh.PloS one · 2013Trial
- Association Between Fresh Gas Flow Rate and Optic Nerve Sheath Diameter During Laparoscopic Cholecystectomy: A Prospective Observational Study.Journal of clinical medicine · 2026Article
- Longitudinal Peripartum Assessment of Retinal Nerve Fiber Layer Thickness and Optic Nerve Sheath Diameter in Women with Preeclampsia and Normotensive Pregnant Controls.Journal of clinical medicine · 2026Article
- Dynamic response of optic nerve sheath diameter to PaCOJournal of clinical monitoring and computing · 2026Article
- Article
- Optic Nerve Sheath Diameter and Transcranial Doppler Pulsatility Index for Non-Invasive ICP Assessment in Acute Intracerebral Hemorrhage.Brain sciences · 2026Article
- Ultrasonographic optic nerve sheath diameter for predicting elevated intracranial pressure and clinical severity in children: a prospective observational study.European journal of pediatrics · 2026Observational
- Characterizing Initial Cervical Spine and Neurovascular Findings in 84 Consecutive Patients with Hypermobile Ehlers-Danlos Syndrome: A Retrospective Study.Journal of clinical medicine · 2026Article
- Association between perioperative optic nerve sheath diameter and postoperative delirium after Bentall surgery: a prospective observational study.Frontiers in medicine · 2026Article
- Systematic review of the diagnostic accuracy of noninvasive intracranial pressure monitoring using optic nerve sheath diameter and the Brain4Care system.Brain & spine · 2026Review
- Automated Semisupervised Measurement of Optic Nerve Sheath Diameter From CT Following Traumatic Brain Injury.International journal of biomedical imaging · 2026Article
- Dose-dependent reduction of optic nerve sheath diameter during graded lower body negative pressure in healthy adults of both sexes.Frontiers in network physiology · 2026Article
- Article
- A prospective study of transorbital ultrasound multimodal imaging in the detection and evaluation of increased intracranial pressure.BMC medical imaging · 2025Article
66 more citing papers are in PubMed but not listed here.
Corrections and comments
- Commented on by
Authors and funding
6 authors at 3 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
introductionThe optic nerve sheath diameter (ONSD) may be increased in brain-injured patients, especially children, with intracranial hypertension. We investigated whether measurements of ONSD correlated with simultaneous noninvasive and invasive measurements of the intracranial pressure (ICP) in brain-injured adults.
methodsSeventy-six critical care patients (58 males; 47 +/- 18 years old) were included in the study. Fifty patients suffered from brain injury, whereas 26 had no intracranial pathology and served as control individuals. Initially, brain-injured patients were evaluated clinically (Glasgow Coma Scale) and using a semiquantitative (I to VI) neuroimaging scale (Marshall Scale). Thereafter, the patients were divided into those with moderate (Marshall Scale = I and Glasgow Coma Scale > 8 [n = 18]) and severe (Marshall Scale = II to VI and Glasgow Coma Scale < or =8 [n = 32]) brain injury. All patients underwent noninvasive measurement of the ICP (estimated ICP) by transcranial Doppler sonography, and synchronous ONSD measurements by optic nerve sonography. Finally, invasive ICP measurement using an intraparenchymal catheter was performed in patients with severe brain injury.
resultsONSD and estimated ICP were both significantly increased (6.1 +/- 0.7 mm and 26.2 +/- 8.7 mmHg, respectively; P < 0.0001) in patients with severe brain injury as compared with patients with moderate brain injury (4.2 +/- 1.2 mm and 12.0 +/- 3.6 mmHg) and compared with control individuals (3.6 +/- 0.6 mm and 10.3 +/- 3.1 mmHg). Furthermore, in patients with severe brain injury the ONSD measurements were strongly correlated with estimated ICP values (r = 0.80, P < 0.0001) as well as with the neuroimaging scale results (r = 0.82, P < 0.001). In the patients with severe brain injury, ONSD measurements correlated with invasive ICP values (r = 0.68, P = 0.002). The best cut-off value of ONSD for predicting elevated ICP was 5.7 mm (sensitivity = 74.1% and specificity = 100%).
conclusionONSD measurements correlate with noninvasive and invasive measurements of the ICP, and with head computed tomography scan findings in brain-injured adults. Hence, optic nerve sonography may serve as an additional diagnostic tool that could alert clinicians to the presence of elevated ICP, whenever invasive ICP evaluation is contraindicated and/or is not available. This trial is International Standard Randomised Controlled Trial Number registered (ISRCTN 91941687).
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.