ArticleBMC medical research methodology2008
Unit-specific calibration of Actigraph accelerometers in a mechanical setup - is it worth the effort? The effect on random output variation caused by technical inter-instrument variability in the laboratory and in the field.
Article in BMC medical research methodology, 2008. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
8 citing papers in PubMed.
- Comparison of Two Generations of ActiGraph Accelerometers: The CARDIA Study.Medicine and science in sports and exercise · 2018Article
- Reliability of the Actigraph GT3X+ Accelerometer in Adults under Free-Living Conditions.PloS one · 2015Article
- Optimal sensor placement for measuring physical activity with a 3D accelerometer.Sensors (Basel, Switzerland) · 2014Article
- The use of individual cut points from treadmill walking to assess free-living moderate to vigorous physical activity in obese subjects by accelerometry: is it useful?BMC medical research methodology · 2012Article
- Mechanical and free living comparisons of four generations of the Actigraph activity monitor.The international journal of behavioral nutrition and physical activity · 2012Article
- The effectiveness of a community playground intervention.Journal of urban health : bulletin of the New York Academy of Medicine · 2012Article
- Comparison of four ActiGraph accelerometers during walking and running.Medicine and science in sports and exercise · 2010Article
- Review of physical activity measurement using accelerometers in older adults: considerations for research design and conduct.Preventive medicine · 2009Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundPotentially, unit-specific in-vitro calibration of accelerometers could increase field data quality and study power. However, reduced inter-unit variability would only be important if random instrument variability contributes considerably to the total variation in field data. Therefore, the primary aim of this study was to calculate and apply unit-specific calibration factors in multiple accelerometers in order to examine the impact on random output variation caused by inter-instrument variability.
methodsInstrument-specific calibration factors were estimated in 25 MTI- and 53 CSA accelerometers in a mechanical setup using four different settings varying in frequencies and/or amplitudes. Calibration effect was analysed by comparing raw and calibrated data after applying unit-specific calibration factors to data obtained during quality checks in a mechanical setup and to data collected during free living conditions.
resultsCalibration reduced inter-instrument variability considerably in the mechanical setup, both in the MTI instruments (raw SDbetween units = 195 counts*min-1 vs. calibrated SDbetween units = 65 counts*min-1) and in the CSA instruments (raw SDbetween units = 343 counts*min-1 vs. calibrated SDbetween units = 67 counts*min-1). However, the effect of applying the derived calibration to children's and adolescents' free living physical activity data did not alter the coefficient of variation (CV) (children: CVraw = 30.2% vs. CVcalibrated = 30.4%, adolescents: CVraw = 36.3% vs. CVcalibrated = 35.7%). High correlations (r = 0.99 & r = 0.98, respectively) were observed between raw and calibrated field data, and the proportion of the total variation caused by the MTI- and CSA monitor was estimated to be only 1.1% and 4.2%, respectively. Compared to the CSA instruments, a significantly increased (9.95%) mean acceleration response was observed post hoc in the batch of MTI instruments, in which a significantly reduced inter-instrumental reliability was observed over time.
conclusionThe application of unit-specific calibration factors to data collected during free living conditions had no apparent effect on inter-instrument variability. In all probability, the effect of technical calibration was primarily attenuated in the field by other more dominant sources of variation. However, routine technical assessments are still very important for determining the acceleration responses in the batch of instruments being used and, if performed after every field use, for preventing decidedly broken instruments from being returned into the field repeatedly.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.