ArticleMedical physics2008
A practical global distortion correction method for an image intensifier based x-ray fluoroscopy system.
Article in Medical physics, 2008. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT02737579 (XFM), which is not on this map. Cited by 12 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
XFM: (X-ray Fused With MRI) Guided Cardiac Catheterization
Who cites it
12 citing papers in PubMed.
- Enhancing Single-Plane Fluoroscopy: A Self-Calibrating Bundle Adjustment for Distortion Modeling.Diagnostics (Basel, Switzerland) · 2024Article
- Transfer learning from an artificial radiograph-landmark dataset for registration of the anatomic skull model to dual fluoroscopic X-ray images.Computers in biology and medicine · 2021Article
- Multi-body 3D-2D registration for image-guided reduction of pelvic dislocation in orthopaedic trauma surgery.Physics in medicine and biology · 2020Article
- 36M-pixel synchrotron radiation micro-CT for whole secondary pulmonary lobule visualization from a large human lung specimen.European journal of radiology open · 2020Article
- Image intensifier distortion influences a surgeon's ability to aim guidewires during orthopaedic procedures.Skeletal radiology · 2019Article
- Intra-operative fiducial-based CT/fluoroscope image registration framework for image-guided robot-assisted joint fracture surgery.International journal of computer assisted radiology and surgery · 2017Article
- Geometric calibration and correction for a lens-coupled detector in x-ray phase-contrast imaging.Journal of medical imaging (Bellingham, Wash.) · 2017Article
- Multimodality calibration for simultaneous fluoroscopic and nuclear imaging.EJNMMI physics · 2016Article
- Image intensifier distortion correction for fluoroscopic RSA: the need for independent accuracy assessment.Journal of applied clinical medical physics · 2012Article
- X-ray magnetic resonance fusion to internal markers and utility in congenital heart disease catheterization.Circulation. Cardiovascular imaging · 2011Article
- Robust automatic rigid registration of MRI and X-ray using external fiducial markers for XFM-guided interventional procedures.Medical physics · 2011Article
- Interventional cardiovascular magnetic resonance: still tantalizing.Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance · 2008Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
Abstract
X-ray images acquired on systems with image intensifiers (II) exhibit characteristic distortion which is due to both external and internal factors. The distortion is dependent on the orientation of the II, a fact particularly relevant to II's mounted on C arms which have several degrees of freedom of motion. Previous descriptions of distortion correction strategies have relied on a dense sampling of the C-arm orientation space, and as such have been limited mostly to a single arc of the primary angle, alpha. We present a new method which smooths the trajectories of the segmented vertices of the grid phantom as a function of a prior to solving the two-dimensional warping problem. It also shows that the same residual errors of distortion correction could be achieved without fitting the trajectories of the grid vertices, but instead applying the previously described global method of distortion correction, followed by directly smoothing the values of the polynomial coefficients as functions of the C-arm orientation parameters. When this technique was applied to a series of test images at arbitrary alpha, the root-mean-square (RMS) residual error was 0.22 pixels. The new method was extended to three degrees of freedom of the C-arm motion: the primary angle, alpha; the secondary angle, beta; and the source-to-intensifier distance, lambda. Only 75 images were used to characterize the distortion for the following ranges: alpha, +/- 45 degrees (Deltaalpha = 22.5 degrees); beta, +/- 36 degrees (Deltabeta = 18 degrees); lambda, 98-118 cm (Deltalambda = 10 cm). When evaluated on a series of test images acquired at arbitrary (alpha, beta, lambda), the RMS residual error was 0.33 pixels. This method is targeted at applications such as guidance of catheter-based interventions and treatment planning for brachytherapy, which require distortion-corrected images over a large range of C-arm orientations.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.