Evidence map›Paper›PMID 18359246›Full record

ArticleJournal of the American Society for Mass Spectrometry2008

Electron capture dissociation implementation progress in Fourier transform ion cyclotron resonance mass spectrometry.

Yury O Tsybin, John P Quinn, Oleg Yu Tsybin, Christopher L Hendrickson, Alan G Marshall

Open access · greenAbstract read
PubMed Publisher
In one paragraph

Article in Journal of the American Society for Mass Spectrometry, 2008. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed
1.8field-weighted citation impact, top 17% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed, 39 citations in OpenAlex.

  1. Article
  2. Absorption Mode Broadband 2D MS for Proteomics and Metabolomics.Journal of the American Society for Mass Spectrometry · 2026
    Article
  3. Analytical applications of gas-phase ion chemistry enabled by mass spectrometry.Analytical methods : advancing methods and applications · 2026
    Review
  4. Article
  5. Article
  6. Article
  7. Relative stability of peptide sequence ions generated by tandem mass spectrometry.Journal of the American Society for Mass Spectrometry · 2012
    Article
  8. Article
  9. Article
  10. Article
  11. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 4 institutions in 3 countries.

Yury O TsybinBiomolecular Mass Spectrometry Laboratory, Ecole Polytechnique Fédérale de Lausanne, Lausanne, Switzerland. yury.tsybin@epfl.ch
John P Quinn
Oleg Yu Tsybin
Christopher L Hendrickson
Alan G Marshall
Florida State University · USÉcole Polytechnique Fédérale de Lausanne · CHNational High Magnetic Field Laboratory · USPeter the Great St. Petersburg Polytechnic University · RU

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Successful electron capture dissociation (ECD) Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS) applications to peptide and protein structural analysis have been enabled by constant progress in implementation of improved electron injection techniques. The rate of ECD product ion formation has been increased to match the liquid chromatography and capillary electrophoresis timescales, and ECD has been combined with infrared multiphoton dissociation in a single experimental configuration to provide simultaneous irradiation, fast switching between the two techniques, and good spatial overlap between ion, photon, and electron beams. Here we begin by describing advantages and disadvantages of the various existing electron injection techniques for ECD in FT-ICR MS. We next compare multiple-pass and single-pass ECD to provide better understanding of ECD efficiency at low and high negative cathode potentials. We introduce compressed hollow electron beam injection to optimize the overlap of ion, photon, and electron beams in the ICR ion trap. Finally, to overcome significant outgassing during operation of a powerful thermal cathode, we introduce nonthermal electron emitter-based electron injection. We describe the first results obtained with cold cathode ECD, and demonstrate a general way to obtain low-energy electrons in FT-ICR MS by use of multiple-pass ECD.

Indexed as

AlgorithmsCyclotronsElectronsIonsSpectrometry, Mass, Electrospray IonizationSpectroscopy, Fourier Transform InfraredIons

Identifiers

PMID18359246
OpenAlexW2037860871

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.