ArticleOptics letters2008
Precision steering of an optical trap by electro-optic deflection.
Article in Optics letters, 2008. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 19 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
19 citing papers in PubMed.
- High-Speed Optical Traps Address Dynamics of Processive and Non-Processive Molecular Motors.Methods in molecular biology (Clifton, N.J.) · 2022Article
- Optical Micromachines for Biological Studies.Micromachines · 2020Review
- Single molecule mechanics resolves the earliest events in force generation by cardiac myosin.eLife · 2019Article
- Cargo diffusion shortens single-kinesin runs at low viscous drag.Scientific reports · 2019Article
- KIF15 nanomechanics and kinesin inhibitors, with implications for cancer chemotherapeutics.Proceedings of the National Academy of Sciences of the United States of America · 2018Article
- Electro-optic deflectors deliver advantages over acousto-optical deflectors in a high resolution, ultra-fast force-clamp optical trap.Optics express · 2018Article
- Full molecular trajectories of RNA polymerase at single base-pair resolution.Proceedings of the National Academy of Sciences of the United States of America · 2018Article
- Intraflagellar transport velocity is governed by the number of active KIF17 and KIF3AB motors and their motility properties under load.Proceedings of the National Academy of Sciences of the United States of America · 2017Article
- The Mechanochemical Cycle of Mammalian Kinesin-2 KIF3A/B under Load.Current biology : CB · 2015Article
- Article
- Kinesin processivity is gated by phosphate release.Proceedings of the National Academy of Sciences of the United States of America · 2014Article
- An improved optical tweezers assay for measuring the force generation of single kinesin molecules.Methods in molecular biology (Clifton, N.J.) · 2014Article
- Interrogating biology with force: single molecule high-resolution measurements with optical tweezers.Biophysical journal · 2013Review
- Construction of a high resolution microscope with conventional and holographic optical trapping capabilities.Journal of visualized experiments : JoVE · 2013Article
- Dynamic Force Sensing Using an Optically Trapped Probing System.IEEE/ASME transactions on mechatronics : a joint publication of the IEEE Industrial Electronics Society and the ASME Dynamic Systems and Control Division · 2011Article
- A universal pathway for kinesin stepping.Nature structural & molecular biology · 2011Article
- Moving into the cell: single-molecule studies of molecular motors in complex environments.Nature reviews. Molecular cell biology · 2011Review
- Invited review article: Imaging techniques for harmonic and multiphoton absorption fluorescence microscopy.The Review of scientific instruments · 2009Review
- Single molecule transcription elongation.Methods (San Diego, Calif.) · 2009Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
Abstract
We designed, constructed, and tested a single-beam optical trapping instrument employing twin electro-optic deflectors (EODs) to steer the trap in the specimen plane. Compared with traditional instruments based on acousto-optic deflectors (AODs), EOD-based traps offer a significant improvement in light throughput and a reduction in deflection-angle (pointing) errors. These attributes impart improved force and position resolution, making EOD-based traps a promising alternative for high-precision nanomechanical measurements of biomaterials.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.