SynthesisThe Cochrane database of systematic reviews2008
Devices and pressure sources for administration of nasal continuous positive airway pressure (NCPAP) in preterm neonates.
Synthesis in The Cochrane database of systematic reviews, 2008. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT07773896 (The Effect of Infant Massage Applied at Different Durations on Comfort and Physiological Stability in Late Preterm Infants Receiving nCPAP), which is not on this map. Cited by 43 papers, 8 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
The Effect of Infant Massage Applied at Different Durations on Comfort and Physiological Stability in Late Preterm Infants Receiving nCPAP
Who cites it
43 citing papers in PubMed, 8 syntheses or guidelines pooled it, 298 citations in OpenAlex.
- Nasal continuous positive airway pressure immediately after extubation for preventing morbidity in preterm infants.The Cochrane database of systematic reviews · 2024Pooled it
- Continuous positive airway pressure (CPAP) for apnoea of prematurity.The Cochrane database of systematic reviews · 2023Pooled it
- Masks versus prongs as interfaces for nasal continuous positive airway pressure in preterm infants.The Cochrane database of systematic reviews · 2022Pooled it
- Nasal continuous positive airway pressure levels for the prevention of morbidity and mortality in preterm infants.The Cochrane database of systematic reviews · 2021Pooled it
- Continuous positive airway pressure (CPAP) for respiratory distress in preterm infants.The Cochrane database of systematic reviews · 2020Pooled it
- Porcine vs bovine surfactant therapy for preterm neonates with RDS: systematic review with biological plausibility and pragmatic meta-analysis of respiratory outcomes.Respiratory research · 2019Pooled it
- High flow nasal cannula for respiratory support in preterm infants.The Cochrane database of systematic reviews · 2016Pooled it
- Continuous distending pressure for respiratory distress in preterm infants.The Cochrane database of systematic reviews · 2015Pooled it
- Systematic rotation versus continuous application of 'nasal prongs' or 'nasal mask' in preterm infants on nCPAP: a randomized controlled trial.European journal of pediatrics · 2023Trial
- The Effect of Extended Continuous Positive Airway Pressure on Changes in Lung Volumes in Stable Premature Infants: A Randomized Controlled Trial.The Journal of pediatrics · 2020Trial
- Nasal masks or binasal prongs for delivering continuous positive airway pressure in preterm neonates-a randomised trial.European journal of pediatrics · 2017Trial
- CeasIng Cpap At standarD criteriA (CICADA): predicting a successful outcome.European journal of pediatrics · 2016Trial
- Nasal Jet-CPAP (variable flow) versus Bubble-CPAP in preterm infants with respiratory distress: an open label, randomized controlled trial.Journal of perinatology : official journal of the California Perinatal Association · 2015Trial
- Influence of nose and mouth leaks on peripheral oxygen saturation during continuous positive airway pressure in neonates.World journal of pediatrics : WJP · 2013Trial
- OcclusiveEuropean respiratory review : an official journal of the European Respiratory Society · 2026Review
- Correlation between nasal anatomical characteristics in newborns and short binasal prong dimensions.Jornal de pediatria · 2023Article
- Bubble devices versus other pressure sources for nasal continuous positive airway pressure in preterm infants.The Cochrane database of systematic reviews · 2023Review
- Satisfaction of Health Professionals Regarding the Short Binasal Prong Used as a Non-Invasive Ventilation Interface in Neonatology.Journal of multidisciplinary healthcare · 2023Article
- Non-invasive ventilation in neonates: a review of current literature.Frontiers in pediatrics · 2023Review
- Practical aspects on the use of non-invasive respiratory support in preterm infants.International journal of pediatrics & adolescent medicine · 2020Review
Corrections and comments
- Update of
Authors and funding
4 authors at 3 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundNasal continuous positive airway pressure (NCPAP) is used to support preterm infants recently extubated, those experiencing significant apnoea of prematurity and those with respiratory distress soon after birth as an alternative to intubation and ventilation. This review focuses exclusively on identifying the most effective pressure source and interface for NCPAP delivery in preterm infants.
objectivesTo determine which technique of pressure generation and which type of nasal interface for NCPAP delivery most effectively reduces the need for additional respiratory support in preterm infants extubated to NCPAP following intermittent positive pressure ventilation (IPPV) for respiratory distress syndrome (RDS) or in those treated with NCPAP soon after birth. SEARCH STRATEGY: The strategy included searches of MEDLINE (1966 - 2006), the Cochrane Central Register of Controlled Trials (CENTRAL, The Cochrane Library, Issue 4, 2006) CINAHL, abstracts from conference proceedings, cross-referencing of previous reviews and the use of expert informants. SELECTION CRITERIA: Randomised or quasi-randomised trials comparing different techniques of NCPAP pressure generation and/or nasal interfaces in preterm infants extubated to NCPAP following IPPV for RDS or treated with NCPAP soon after birth. DATA COLLECTION AND ANALYSIS: Data was extracted and analysed by the first three authors. Dichotomous results were analysed using the relative risk (RR), risk difference (RD) and number needed to treat (NNT). MAIN
results1. Preterm infants being extubated to NCPAP following a period of IPPV for RDS:Meta-analysis of the results from Davis 2001 and Roukema 1999a demonstrated that short binasal prongs are more effective at preventing re-intubation than single nasal or nasopharyngeal prongs [typical RR 0.59 (CI: 0.41, 0.85), typical RD -0.21 (CI: -0.35, -0.07), NNT 5 (CI: 3, 14)]. In one study comparing short binasal prong devices (Sun 1999), the re-intubation rate was significantly lower with the Infant Flow Driver than with the Medicorp prong [RR 0.33 (CI: 0.17, 0.67), RD -0.32 (CI: -0.49, -0.15), NNT 3 (CI: 2, 7)]. The other study comparing short binasal prong devices (Infant Flow Driver versus INCA prongs, Stefanescu 2003) demonstrated no significant difference in the re-intubation rate but did show a significant reduction in the total days in hospital in the Infant Flow Driver group [MD -12.60 (95% CI: -22.81, -2.39) days].2. Preterm infants primarily treated with NCPAP soon after birth:In the one trial identified, Mazzella 2001 found a significantly lower oxygen requirement and respiratory rate in those randomised to short binasal prongs when compared with CPAP delivered via nasopharyngeal prong. The requirement for intubation beyond 48 hours from randomisation was not assessed.3. Studies randomising preterm infants to different NCPAP systems using broad inclusion criteriaThe studies of Rego 2002 and Buettiker 2004 did not examine the primary outcomes of this review. Of the secondary outcomes, Rego 2002 demonstrated a significantly higher incidence of nasal hyperaemia with the use of the Argyle prong compared with Hudson prongs [RR 2.39 (95% CI: 1.27, 4.50), RD 0.28 (95% CI: 0.10, 0.46)]. One study comparing different techniques of pressure generation is awaiting further assessment as it is currently available in abstract form only. AUTHORS'
conclusionsShort binasal prong devices are more effective than single prongs in reducing the rate of re-intubation. Although the Infant Flow Driver appears more effective than Medicorp prongs the most effective short binasal prong device remains to be determined. The improvement in respiratory parameters with short binasal prongs suggests they are more effective than nasopharyngeal CPAP in the treatment of early RDS. Further studies incorporating longer-term outcomes are required. Studies are also needed to determine the optimal pressure source for the delivery of NCPAP.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.