ArticleEuropean journal of nuclear medicine and molecular imaging2008
Degradation of myocardial perfusion SPECT images caused by contaminants in thallous (201Tl) chloride.
Article in European journal of nuclear medicine and molecular imaging, 2008. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed, 5 citations in OpenAlex.
- Comments on contaminants in thallous (201Tl) chloride.European journal of nuclear medicine and molecular imaging · 2008Article
Corrections and comments
- Commented on by
Authors and funding
4 authors at 3 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeThallous (201Tl) chloride is a single-photon emission computed tomography (SPECT) tracer mainly used for assessing perfusion and viability of myocardial tissue. 201Tl emits X-rays around 72 keV and gammas at 167 keV, and has a half-life of 73 h. Regulations allow an intrinsic contamination up to 3-5%, which is mainly caused by 200Tl (368 keV; 26 h) and by 202Tl (439 keV; 12.2 days). Contra-intuitive to the low-level percentages in which these contaminants are present, their impact may be significant because of much higher gamma camera sensitivity for these high-energy photon emissions. Therefore, we investigate the effects of the contaminants in terms of detected fractions of photons in projections and contrast degradation in reconstructed images.
methodsAcquisitions of a digital thorax phantom filled with thallous (201Tl) chloride were simulated with a validated Monte Carlo tool, thereby, modelling 1% of contamination by 200Tl and 202Tl each. In addition, measurements of a thorax phantom on a dual-headed gamma camera were performed. The product used was contaminated by 0.17% of 200Tl and 0.24% of 202Tl at activity reference time (ART). This ART is specified by the manufacturer, thereby, accounting for the difference in half-lives of 201Tl and its contaminants. These measurements were repeated at different dates associated with various contamination levels.
resultsSimulations showed that, with 1% of 200Tl and 202Tl, the total contamination in the 72 keV window can rise up to one out of three detected photons. For the 167 keV window, the contamination is even more pronounced: more than four out of five detections in this photopeak window originate from contaminants. Measurements indicate that cold lesion contrast in myocardial perfusion SPECT imaging is at maximum close to ART. In addition to a higher noise level, relative contrast decreases 15% 2 days early to ART, which is explained by an increase in 200Tl contamination. After ART, contrast decreased by 16% when the 202Tl contamination increased to the maximal allowed limit.
conclusionsContra-intuitive to the low-level percentages in which they are typically present, penetration and downscatter of high-energy photons from 200Tl and 202Tl significantly contribute to thallous (201Tl) chloride images, thereby, reducing contrast and adding noise. These findings may prompt for improved production methods, for updated policies with regard to timing of usage, and they also render the usefulness of adding the high photopeak window (167 keV) questionable. A window-based correction method for this contamination is advisable.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.