Evidence map›Paper›PMID 18173647›Full record

ArticleJournal of microscopy2008

Raster image correlation spectroscopy (RICS) for measuring fast protein dynamics and concentrations with a commercial laser scanning confocal microscope.

C M Brown, R B Dalal, B Hebert, M A Digman, A R Horwitz, E Gratton

Open access · bronzeAbstract read
In one paragraph

Article in Journal of microscopy, 2008. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 99 papers.

0numbers the graph read from it
0cells of the map it votes in
99citing papers in PubMed
12.0field-weighted citation impact, top 2% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

99 citing papers in PubMed, 190 citations in OpenAlex.

  1. Article
  2. Review
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Review
  12. Article
  13. Review
  14. Article
  15. Article
  16. Article
  17. Article
  18. Article
  19. Article
  20. Review

39 more citing papers are in PubMed but not listed here.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 2 countries.

C M BrownMcGill University Life Sciences Complex Imaging Facility, Department of Biochemistry, Montreal, Quebec, Canada. claire.brown@mcgill.ca
R B Dalal
B Hebert
M A Digman
A R Horwitz
E Gratton
McGill University · CAUniversity of Virginia · US

Funding

STRUCTUREU54GM064346 · NIGMS · UNIVERSITY OF VIRGINIA CHARLOTTESVILLE · PI IMPERIALI, BARBARA · 2001 to 2010
$74.9M
YEAST RIBOSOMAL STALK COMPOSITION IN VIVO BY TWO-PHOTON FCS AND PCH ANALYSISP41RR003155 · NCRR · UNIVERSITY OF ILLINOIS URBANA-CHAMPAIGN · PI GRATTON, ENRICO · 1986 to 2011
$14.9M
DETERMINANTS OF MYOGENIC MEMBRANE PHENOMENAR01GM023244 · NIGMS · UNIVERSITY OF VIRGINIA CHARLOTTESVILLE · PI HORWITZ, ALAN F. "RICK" · 1985 to 2014
$6.7M
DETERMINANTS OF MYOGENIC MEMBRANE PHENOMENAR37GM023244 · NIGMS · UNIVERSITY OF VIRGINIA CHARLOTTESVILLE · PI HORWITZ, ALAN F · 1992 to 2002
$1.1M
NCRR NIH HHS 5 P41 RR003155NCRR NIH HHS P41 RR003155NIGMS NIH HHS GM23244NIGMS NIH HHS R01 GM023244NIGMS NIH HHS R37 GM023244NIGMS NIH HHS U54 GM064346NIGMS NIH HHS U54 GM64346
6 · The paper itself

Abstract

Raster image correlation spectroscopy (RICS) is a new and novel technique for measuring molecular dynamics and concentrations from fluorescence confocal images. The RICS technique extracts information about molecular dynamics and concentrations from images of living cells taken on commercial confocal systems. Here we develop guidelines for performing the RICS analysis on an analogue commercial laser scanning confocal microscope. Guidelines for typical instrument settings, image acquisition settings and analogue detector characterization are presented. Using appropriate instrument/acquisition parameters, diffusion coefficients and concentrations can be determined, even for highly dynamic dye molecules in solution. Standard curves presented herein demonstrate the ability to detect protein concentrations as low as approximately 2 nM. Additionally, cellular measurements give accurate values for the diffusion of paxillin-enhanced-green fluorescent protein (EGFP), an adhesion adaptor molecule, in the cytosol of the cell and also show slower paxillin dynamics near adhesions where paxillin interacts with immobile adhesion components. Methods are presented to account for bright immobile structures within the cell that dominate spatial correlation functions; allowing the extraction of fast protein dynamics within and near these structures. A running average algorithm is also presented to address slow cellular movement or movement of cellular features such as adhesions. Finally, methods to determine protein concentration in the presence of immobile structures within the cell are presented. A table is presented giving guidelines for instrument and imaging setting when performing RICS on the Olympus FV300 confocal and these guidelines are a starting point for performing the analysis on other commercial confocal systems.

Indexed as

Cells, CulturedGreen Fluorescent ProteinsMicroscopy, ConfocalPaxillinProteinsSpectrum AnalysisGreen Fluorescent ProteinsPaxillinProteins

Identifiers

PMID18173647
PMCPMC3690660
OpenAlexW2010181298

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.