ArticleJournal of fluorescence2008
Probing DNA hybridization in homogeneous solution and at interfaces via measurement of the intrinsic fluorescence decay time of a single label.
Article in Journal of fluorescence, 2008. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Nucleic acid-based fluorescent probes and their analytical potential.Analytical and bioanalytical chemistry · 2011Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
2 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The hybridization of DNA oligomers including molecular beacons can be detected by measurement of either the decay time or the intensity of a single fluorescent label attached to the end of the respective oligonucleotide. The method works both in solution and solid phase and can distinguish between fully complementary and mismatch sequences as demonstrated for a 15-mer oligonucleotide and a 25-mer molecular beacon. The fluorescence lifetime method is advantageous in (a) requiring a single label (and therefore a single labeling step) only; and (b), being based on measurement of a self-referenced magnitude that is hardly affected by parameters such as fluctuations in light intensity that make measurement of intensity more prone to interferences.
Indexed as
Identifiers
18092141What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.