Evidence map›Paper›PMID 18078912›Full record

ArticleAcademic radiology2008

Temporally targeted imaging method applied to ECG-gated computed tomography: preliminary phantom and in vivo experience.

Brian E Nett, Shuai Leng, Joseph N Zambelli, Scott B Reeder, Michael A Speidel, Guang-Hong Chen

Abstract read
In one paragraph

Article in Academic radiology, 2008. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Brian E NettDepartment of Medical Physics, University of Wisconsin Madison, J5/M174, Clinical Science Center, 600 Highland Avenue, Madison, WI 53792-1590, USA.
Shuai Leng
Joseph N Zambelli
Scott B Reeder
Michael A Speidel
Guang-Hong Chen

Funding

U.W. RADIOLOGICAL SCIENCES TRAINING PROGRAMT32CA009206 · NCI · UNIVERSITY OF WISCONSIN-MADISON · PI Bryan Patrick Bednarz · 1985 to 2026
$12.1M
Integrated Tomosynthetic Perfusion and Cone-beam CT Imaging on a C-arm GantryR01EB005712 · NIBIB · UNIVERSITY OF WISCONSIN-MADISON · PI CHEN, GUANG-HONG · 2006 to 2009
$1.4M
Reduced Dose Neuro CT perfusion Using HYPRR01EB007021 · NIBIB · UNIVERSITY OF WISCONSIN-MADISON · PI ROWLEY, HOWARD A · 2006 to 2009
$1.3M
NCI NIH HHS 5T32CA009206NCI NIH HHS T32 CA009206NIBIB NIH HHS R01 EB005712NIBIB NIH HHS R01EB005712NIBIB NIH HHS R01 EB007021
6 · The paper itself

Abstract

RATIONALE AND

objectivesExisting cardiac imaging methods do not allow for improved temporal resolution when considering a targeted region of interest (ROI). The imaging method presented here enables improved temporal resolution for ROI imaging (namely, a reconstruction volume smaller than the complete field of view). Clinically, temporally targeted reconstruction would not change the primary means of reconstructing and evaluating images, but rather would enable the adjunct technique of ROI imaging, with improved temporal resolution compared with standard reconstruction ( approximately 20% smaller temporal scan window). In gated cardiac computed tomography (CT) scans improved temporal resolution directly translates into a reduction in motion artifacts for rapidly moving objects such as the coronary arteries. MATERIALS AND

methodsRetrospectively electrocardiogram gated coronary angiography data from a 64-slice CT system were used. A motion phantom simulating the motion profile of a coronary artery was constructed and scanned. Additionally, an in vivo study was performed using a porcine model. Comparisons between the new reconstruction technique and the standard reconstruction are given for an ROI centered on the right coronary artery, and a pulmonary ROI.

resultsIn both a well-controlled motion model and a porcine model results show a decrease in motion induced artifacts including motion blur and streak artifacts from contrast enhanced vessels within the targeted ROIs, as assessed through both qualitative and quantitative observations.

conclusionTemporally targeted reconstruction techniques demonstrate the potential to reduce motion artifacts in coronary CT. Further study is warranted to demonstrate the conditions under which this technique will offer direct clinical utility. Improvement in temporal resolution for gated cardiac scans has implications for improving: contrast enhanced CT angiography, calcium scoring, and assessment of the pulmonary anatomy.

Indexed as

Coronary VesselsElectrocardiographyAnimalsArtifactsCoronary AngiographyImage Processing, Computer-AssistedMotionPhantoms, ImagingPilot ProjectsRetrospective StudiesSwineTime FactorsTomography, X-Ray Computed

Identifiers

PMID18078912
PMCPMC2693077

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.