Evidence map›Paper›PMID 17990081›Full record

ArticleJournal of materials science. Materials in medicine2008

Long-term assessment of the implant titanium material--artificial saliva interface.

M V Popa, E Vasilescu, P Drob, C Vasilescu, I Demetrescu, D Ionita

Abstract read
PubMed Publisher
In one paragraph

Article in Journal of materials science. Materials in medicine, 2008. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
4.8field-weighted citation impact, top 7% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 44 citations in OpenAlex.

  1. Review
  2. Article
  3. Stability of plasma electrolytic oxidation coating on titanium in artificial saliva.Journal of materials science. Materials in medicine · 2013
    Article
  4. Functionalization of titanium based metallic biomaterials for implant applications.Journal of materials science. Materials in medicine · 2011
    Article
  5. Biocompatibility of orthodontic bands following exposure to dental plaque.Journal of orofacial orthopedics = Fortschritte der Kieferorthopadie : Organ/official journal Deutsche Gesellschaft fur Kieferorthopadie · 2011
    Article
  6. In vitro biocompatibility and corrosion resistance of a new implant titanium base alloy.Journal of materials science. Materials in medicine · 2010
    Article
  7. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

M V PopaInstitute of Physical Chemistry I. G. Murgulescu, Spl. Independentei 202, P.O. Box 12-194, 060021 Bucharest, Romania.
E Vasilescu
P Drob
C Vasilescu
I Demetrescu
D Ionita
Universitatea Națională de Știință și Tehnologie Politehnica București · RO

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This paper studies the long-term (20,000 exposure hours) behavior of titanium and Ti-5Al-4V alloy-Carter-Brugirard saliva interface and the short-term (500 exposure hours) resistance of titanium and Ti-5Al-4V alloy-Tani&Zucchi saliva interface. Potentiodynamic polarization method was applied for the determination of the main electrochemical parameters. Linear polarization measurements for to obtain the corrosion rates were used. Monitoring of the open circuit potentials (E(oc)) for long-term have permitted to calculate the potential gradients due to the pH, DeltaE(oc)(pH) and to the saliva composition DeltaE(oc)(c) changes which can appear "in vivo" conditions and can generate local corrosion. Atomic force microscopy (AFM) has analyzed the surface roughness. Ion release was studied by atomic absorption spectroscopy (AAS). In Carter-Brugirard saliva both titanium and Ti-5Al-4V alloy present very stable passive films, long-term stability, "very good" resistance, low values of the open circuit potential gradients, which cannot generate local corrosion. In Tani&Zucchi artificial saliva, pitting corrosion and noble pitting protection potentials (which cannot be reached in oral cavity) were registered; titanium ion release is very low; surface roughness increase in time and in the presence of the fluoride ions, denoting some increase in the anodic activity.

Indexed as

AluminumBiocompatible MaterialsCorrosionDental AlloysDental MaterialsElectrochemistryEquipment DesignHydrogen-Ion ConcentrationMaterials TestingMicroscopy, Atomic ForceSalivaSaliva, ArtificialTime FactorsTitaniumAluminumBiocompatible MaterialsDental AlloysDental MaterialsSaliva, ArtificialTitanium

Identifiers

PMID17990081
OpenAlexW1981856271

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.