Evidence map›Paper›PMID 17955344›Full record

ArticleThe international journal of cardiovascular imaging2008

CFD analysis in an anatomically realistic coronary artery model based on non-invasive 3D imaging: comparison of magnetic resonance imaging with computed tomography.

Leonid Goubergrits, Ulrich Kertzscher, Bastian Schöneberg, Ernst Wellnhofer, Christoph Petz, Hans-Christian Hege

Abstract readComparative Study
PubMed Publisher
In one paragraph

Article in The international journal of cardiovascular imaging, 2008. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers.

0numbers the graph read from it
0cells of the map it votes in
13citing papers in PubMed
3.2field-weighted citation impact, top 9% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

13 citing papers in PubMed, 50 citations in OpenAlex.

  1. Review
  2. Review
  3. Imaging in Vascular Access.Cardiovascular engineering and technology · 2017
    Review
  4. Article
  5. Observational
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Review
  12. Article
  13. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 3 institutions in 1 country.

Leonid GoubergritsBiofluidmechanics Laboratory, Charité - Universitaetsmedizin Berlin, Spandauer Damm 130, 14050, Berlin, Germany. leonid.goubergrits@charite.de
Ulrich Kertzscher
Bastian Schöneberg
Ernst Wellnhofer
Christoph Petz
Hans-Christian Hege
Charité - Universitätsmedizin Berlin · DEZuse Institute Berlin · DEBerlin Heart (Germany) · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Computational fluid dynamics (CFD) methods based on in vivo three-dimensional vessel reconstructions have recently been shown to provide prognostically relevant hemodynamic data. However, the geometry reconstruction and the assessment of clinically relevant hemodynamic parameters may depend on the used imaging modality. This study compares geometric reconstruction and calculated wall shear stress (WSS) values based on magnetic resonance imaging (MRI) and computed tomography (CT). Both imaging methods were applied to a same 2.5-fold upscale silicon model of the left coronary artery (LCA) main bifurcation. The original model is an optically digitized post mortem vessel cast. This digitized geometry is considered as a "gold standard" or original geometry for the MRI versus CT comparative study. The use of the upscale model allowed generating a high resolution CT raw data set with voxel size of 0.156 x 0.156 x 0.36 mm(3) and a high resolution MRI data set with an equivalent voxel size of 0.196 x 0.196 x 0.196 mm(3) for corresponding in vivo conditions. MRI based reconstruction achieved a mean Hausdorff surface distance of 0.1 mm to the original geometry. This is 2.5 times better than CT based reconstruction with mean Hausdorff surface distance of 0.252 mm. A comparison of the calculated mean WSS shows good correlation (r = 0.97) and good agreement among the three modalities with a WSS of 0.65 Pa in the original model, of 0.68 Pa in the CT based model and of 0.67 Pa in the MRI based model.

Indexed as

Imaging, Three-DimensionalMagnetic Resonance AngiographyModels, AnatomicModels, CardiovascularTomography, X-Ray ComputedBlood PressureCoronary AngiographyCoronary CirculationCoronary VesselsEquipment DesignHemorheologyHumansRegional Blood FlowReplica TechniquesReproducibility of ResultsResearch DesignSilicon

Identifiers

PMID17955344
OpenAlexW2037826195

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.