Evidence map›Paper›PMID 17914864›Full record

ArticleAnalytical chemistry2007

Analytical performance of a venturi-assisted array of micromachined ultrasonic electrosprays coupled to ion trap mass spectrometry for the analysis of peptides and proteins.

Christina Y Hampton, Thomas P Forbes, Mark J Varady, J Mark Meacham, Andrei G Fedorov, F Levent Degertekin, Facundo M Fernández

Open access · greenAbstract read
In one paragraph

Article in Analytical chemistry, 2007. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.

0numbers the graph read from it
0cells of the map it votes in
12citing papers in PubMed
1.7field-weighted citation impact, top 18% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

12 citing papers in PubMed, 26 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 1 country.

Christina Y HamptonSchool of Chemistry and Biochemistry, Georgia Institute of Technology, Atlanta, Georgia 30332, USA.
Thomas P Forbes
Mark J Varady
J Mark Meacham
Andrei G Fedorov
F Levent Degertekin
Facundo M Fernández
Georgia Institute of Technology · USNational Institute of Standards and Technology · US

Funding

Array of Micromachined UltraSonic Electrosprays Bioanalytical Mass SpectrometryR21RR021474 · NCRR · GEORGIA INSTITUTE OF TECHNOLOGY · PI FEDOROV, ANDREI G · 2006 to 2008
$520k
NCRR NIH HHS R21 RR021474NCRR NIH HHS RR021474-01A1
6 · The paper itself

Abstract

The analytical characterization of a novel ion source for mass spectrometry named array of micromachined ultrasonic electrosprays (AMUSE) is presented here. This is a fundamentally different type of ion generation device, consisting of three major components: (1) a piezoelectric transducer that creates ultrasonic waves at one of the resonant frequencies of the sample-filled device, (2) an array of pyramidally shaped nozzles micromachined on a silicon wafer, and (3) a spacer which prevents contact between the array and transducer ensuring the transfer of acoustic energy to the sample. A high-pressure gradient generated at the apexes of the nozzle pyramids forces the periodic ejection of multiple droplet streams from the device. With this device, the processes of droplet formation and droplet charging are separated; hence, the limitations of conventional electrospray-type ion sources, including the need for high charging potentials and the addition of organic solvent to decrease surface tension, can be avoided. In this work, a Venturi device is coupled with AMUSE in order to increase desolvation, droplet focusing, and signal stability. Results show that ionization of model peptides and small tuning molecules is possible with dc charging potentials of 100 Vdc or less. Ionization in rf-only mode (without dc biasing) was also possible. It was observed that, when combined with AMUSE, the Venturi device provides a 10-fold gain in signal-to-noise ratio for 90% aqueous sample solutions. Further reduction in the diameter of the orifices of the micromachined arrays led to an additional signal gain of at least 3 orders of magnitude, a 2-10-fold gain in the signal-to-noise ratio and an improvement in signal stability from 47% to 8.5% RSD. The effectiveness of this device for the soft ionization of model proteins in aqueous media, such as cytochrome c, was also examined, yielding spectra with an average charge state of 8.8 when analyzed with a 100 Vdc charging potential. Ionization of model proteins was also possible in rf-only mode.

Indexed as

UltrasonicsPeptidesProteinsReproducibility of ResultsSensitivity and SpecificitySiliconSpectrometry, Mass, Electrospray IonizationTime FactorsPeptidesProteinsSilicon

Identifiers

PMID17914864
PMCPMC2543123
OpenAlexW1989398258

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.