Evidence map›Paper›PMID 17846886›Full record

ArticleCardiovascular engineering (Dordrecht, Netherlands)2007

Subject-specific model estimation of cardiac output and blood volume during hemorrhage.

Maxwell Lewis Neal, James B Bassingthwaighte

Abstract read
In one paragraph

Article in Cardiovascular engineering (Dordrecht, Netherlands), 2007. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 20 papers.

0numbers the graph read from it
0cells of the map it votes in
20citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

20 citing papers in PubMed.

  1. Trial
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Optimization Framework for Patient-Specific Cardiac Modeling.Cardiovascular engineering and technology · 2019
    Article
  12. Article
  13. Multiscale systems biology of trauma-induced coagulopathy.Wiley interdisciplinary reviews. Systems biology and medicine · 2018
    Review
  14. Article
  15. Article
  16. Article
  17. Review
  18. The Physiome Projects and Multiscale Modeling.IEEE signal processing magazine · 2008
    Article
  19. Article
  20. Error detection and unit conversion.IEEE engineering in medicine and biology magazine : the quarterly magazine of the Engineering in Medicine & Biology Society
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Maxwell Lewis NealDepartment of Medical Education and Biomedical Informatics, University of Washington, Seattle, WA 98195, USA. mneal@u.washington.edu
James B Bassingthwaighte

Funding

Modeling for Heart, Lung, and Blood: From Cell to OrganT15HL088516 · NHLBI · UNIVERSITY OF WASHINGTON · PI BASSINGTHWAIGHTE, JAMES B · 2007 to 2010
$929k
NHLBI NIH HHS T15 HL088516
6 · The paper itself

Abstract

We have developed a novel method for estimating subject-specific hemodynamics during hemorrhage. First, a mathematical model representing a closed-loop circulation and baroreceptor feedback system was parameterized to match the baseline physiology of individual experimental subjects by fitting model results to 1 min of pre-injury data. This automated parameterization process matched pre-injury measurements within 1.4 +/- 1.3% SD. Tuned parameters were then used in similar open-loop models to simulate dynamics post-injury. Cardiac output (CO) estimates were obtained continuously using post-injury measurements of arterial blood pressure (ABP) and heart rate (HR) as inputs to the first open-loop model. Secondarily, total blood volume (TBV) estimates were obtained by summing the blood volumes in all the circulatory segments of a second open-loop model that used measured CO as an additional input. We validated the estimation method by comparing model CO results to flowprobe measurements in 14 pigs. Overall, CO estimates had a Bland-Altman bias of -0.30 l/min with upper and lower limits of agreement 0.80 and -1.40 l/min. The negative bias is likely due to overestimation of the peripheral resistance response to hemorrhage. There was no reference measurement of TBV; however, the estimates appeared reasonable and clearly predicted survival versus death during the post-hemorrhage period. Both open-loop models ran in real time on a computer with a 2.4 GHz processor, and their clinical applicability in emergency care scenarios is discussed.

Indexed as

Blood VolumeCardiac OutputModels, BiologicalAnimalsCardiac Output, LowComputer SimulationDiagnosis, Computer-AssistedHemorrhageSwine

Identifiers

PMID17846886
PMCPMC3629970

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.