ArticleIntensive care medicine2007
Accuracy of bedside capillary blood glucose measurements in critically ill patients.
Article in Intensive care medicine, 2007. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 48 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
48 citing papers in PubMed, 1 synthesis or guideline pooled it, 155 citations in OpenAlex.
- Accuracy of blood-glucose measurements using glucose meters and arterial blood gas analyzers in critically ill adult patients: systematic review.Critical care (London, England) · 2013Pooled it
- Tight glycaemic control by an automated algorithm with time-variant sampling in medical ICU patients.Intensive care medicine · 2008Trial
- A review of hypoglycemia and dextrose treatment in patients with cardiac arrest.Clinical and experimental emergency medicine · 2025Article
- Intermittent scanning continuous glucose monitoring is safe and useful in postsurgical glucose monitoring after pancreatoduodenectomy.Acta diabetologica · 2023Article
- Perioperative glycemic management in adults presenting for elective cardiac and non-cardiac surgery.Perioperative medicine (London, England) · 2023Review
- Comparing the accuracy of point-of-care with laboratory (capillary, venous, and arterial) blood glucose levels in critically ill patients with and without shock.BMC research notes · 2022Article
- Expert consensus on the glycemic management of critically ill patients.Journal of intensive medicine · 2022Article
- Article
- Assessment of changes in blood glucose concentration with intravascular microdialysis.Journal of clinical monitoring and computing · 2018Observational
- What Can We Learn From Point-of-Care Blood Glucose Values Deleted and Repeated by Nurses?Journal of diabetes science and technology · 2018Article
- Accuracy of Capillary and Arterial Whole Blood Glucose Measurements Using a Glucose Meter in Patients under General Anesthesia in the Operating Room.Anesthesiology · 2017Article
- Accuracy and Precision of Measured Blood Sugar Values by Three Glucometers Compared to the Standard Technique.Journal of clinical and diagnostic research : JCDR · 2017Article
- Validity of bedside blood glucose measurement in critically ill patients with intensive insulin therapy.Indian journal of critical care medicine : peer-reviewed, official publication of Indian Society of Critical Care Medicine · 2016Article
- An Elevated Glycemic Gap is Associated with Adverse Outcomes in Diabetic Patients with Acute Myocardial Infarction.Scientific reports · 2016Observational
- Article
- Capillary bedside blood glucose measurement in neonates: missing a diagnosis of galactosemia.Journal of clinical research in pediatric endocrinology · 2015Article
- Accuracy of bedside glucometry in critically ill children with peripheral hypoperfusion.Journal of clinical monitoring and computing · 2015Article
- Inaccuracy of Venous Point-of-Care Glucose Measurements in Critically Ill Patients: A Cross-Sectional Study.PloS one · 2015Article
- Monitoring nutrition and glucose in acute brain injury.Neurocritical care · 2014Review
- Accuracy of point-of-care blood glucose measurements in critically ill patients in shock.Journal of diabetes science and technology · 2014Article
Corrections and comments
- Commented on by
Authors and funding
6 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
objectiveTo compare the accuracy of fingerstick with laboratory venous plasma glucose measurements (laboratory glucose) in medical ICU patients and to determine the factors which interfere with the accuracy of fingerstick measurements.
participantsThe study included 80 consecutive patients aged 58+/-7 years, BMI 29.5+/-9.0, and APACHE II score 15+/-6 (277 simultaneous paired measurements). MEASUREMENTS: This prospective observational study compared fingerstick measurements to simultaneously sampled laboratory glucose once a day in patients in our medical ICU (twice daily if on an insulin infusion). Data recorded included patient demographics, admission diagnoses, APACHE II score, BMI, daily hematocrit, arterial blood gasses, chemistry results, concomitant medications (including vasopressors and corticosteroids), and upper extremity edema. Accuracy was defined as the percentage of paired values not in accord (>15 mg dl(-1)/ 0.83 mmol(-1)l(-1) difference for laboratory values <75 mg dl(-1)/4.12 mmol(-1)l(-1) and >20% difference for laboratory values >or=75 mg/dl). Outliers (blood glucose difference >100 mg dl(-1)/5.56 mmol(-1) l(-1)) were excluded from the correlation and distribution analyses.
resultsMean fingerstick glucose was 129+/-45 mg/dl (7.2+/-2.5 mmol/l) and mean laboratory glucose 123+/-44 mg/dl (6.8+/-2.4 mmol/l). The correlation coefficient between the two values was 0.9110 (Clinical and Laboratory Standards Institute threshold 0.9751). The mean difference (bias) between the two methods was 8.6+/-18.6 mg/dl (0.48+/-1.0 mmol/l) and limits of agreement +45.8 and -28.6 mg/dl (+2.5 and -1.6 mmol/l). Fifty-three (19%) paired measurements in 22 patients were not in accord (CLSI threshold <or=5%). In 44 (83%) of these paired measurements fingerstick glucose was greater than laboratory glucose.
conclusionsThe findings suggest that capillary blood glucose as measured by fingerstick is inaccurate in critically ill ICU patients and does not meet the CLSI standard. It is unclear whether the sampling method, device used, or both contributed to this inaccuracy. The wide limits of agreement suggest that fingerstick measurements should be used with great caution in protocols of tight glycemic control.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.