Evidence map›Paper›PMID 17713844›Full record

ArticlePharmaceutical research2008

Genetically engineered block copolymers: influence of the length and structure of the coiled-coil blocks on hydrogel self-assembly.

Chunyu Xu, Jindrich Kopecek

Abstract read
PubMed Publisher
In one paragraph

Article in Pharmaceutical research, 2008. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 23 papers.

0numbers the graph read from it
0cells of the map it votes in
23citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

23 citing papers in PubMed.

  1. Review
  2. Engineered Protein Hydrogels as Biomimetic Cellular Scaffolds.Advanced materials (Deerfield Beach, Fla.) · 2024
    Review
  3. Article
  4. Microrheology for biomaterial design.APL bioengineering · 2020
    Review
  5. Review
  6. Protein-Engineered Functional Materials.Advanced healthcare materials · 2019
    Review
  7. Article
  8. Article
  9. Scalable manufacturing of biomimetic moldable hydrogels for industrial applications.Proceedings of the National Academy of Sciences of the United States of America · 2016
    Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Smart self-assembled hybrid hydrogel biomaterials.Angewandte Chemie (International ed. in English) · 2012
    Review
  15. Protein-based block copolymers.Biomacromolecules · 2011
    Review
  16. Article
  17. Review
  18. Article
  19. HYDROGELS FROM SOFT CONTACT LENSES AND IMPLANTS TO SELF-ASSEMBLED NANOMATERIALS.Journal of polymer science. Part A, Polymer chemistry · 2009
    Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Chunyu XuDepartment of Pharmaceutics and Pharmaceutical Chemistry, University of Utah, 30 S. 2000 E. Rm. 201, Salt Lake City, Utah 84112, USA.
Jindrich Kopecek

Funding

HYBRID HYDROGELS SELF-ASSEMBLED FROM GRAFT COPOLYMERSR01EB005288 · NIBIB · UNIVERSITY OF UTAH · PI KOPECEK, JINDRICH H. · 2005 to 2008
$1.2M
NIBIB NIH HHS EB005288
6 · The paper itself

Abstract

purposeTo explore the relationship between the structure of block polypeptides and their self-assembly into hydrogels. To investigate structural parameters that influence hydrogel formation and physical properties.

methodsThree ABA triblock and two AB diblock coiled-coil containing polypeptides were designed and biologically synthesized. The triblock polypeptides had two terminal coiled-coil (A) domains and a central random coil (B) segment. The coiled-coil domains were different in their lengths, and tyrosine residues were incorporated at selected solvent-exposed positions in order to increase the overall hydrophobicity of the coiled-coil domains. The secondary structures of these polypeptides were characterized by circular dichroism and analytical ultracentrifugation. The formation of hydrogel structures was evaluated by microrheology and scanning electron microscopy.

resultsHydrogels self-assembled from the triblock polypeptides, and had interconnected network microstructures. Hydrogel formation was reversible. Denaturation of coiled-coil domains by guanidine hydrochloride (GdnHCl) resulted in disassembly of the hydrogels. Removal of GdnHCl by dialysis caused coiled-coil refolding and hydrogel reassembly.

conclusionsProtein ABA triblock polypeptides composed of a central random block flanked by two coiled-coil forming sequences self-assembled into hydrogels. Hydrogel formation and physical properties may be manipulated by choosing the structure and changing the length of the coiled-coil blocks. These self-assembling systems have a potential as in-situ forming depots for protein delivery.

Indexed as

Drug CarriersGenetic EngineeringHydrogelsAmino Acid SequenceCircular DichroismGuanidineHydrophobic and Hydrophilic InteractionsMicroscopy, Electron, ScanningMolecular Sequence DataPeptidesPolyethylene GlycolsPolymersProtein DenaturationProtein FoldingProtein Structure, SecondaryRecombinant ProteinsDrug CarriersGuanidineHydrogelsPeptidesPolyethylene GlycolsPolymersRecombinant ProteinsTyrosine

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.