ArticleNetherlands heart journal : monthly journal of the Netherlands Society of Cardiology and the Netherlands Heart Foundation2007
Clinical implementation of guidelines for cardioverter defibrillator implantation: lost in translation?
Article in Netherlands heart journal : monthly journal of the Netherlands Society of Cardiology and the Netherlands Heart Foundation, 2007. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
6 citing papers in PubMed, 23 citations in OpenAlex.
- Patient barriers to implantable cardioverter defibrillator implantation for the primary prevention of sudden cardiac death in patients with heart failure and reduced ejection fraction.Singapore medical journal · 2016Article
- Implementation of guidelines for implantable cardioverter-defibrillator therapy in clinical practice: Which patients do benefit?Netherlands heart journal : monthly journal of the Netherlands Society of Cardiology and the Netherlands Heart Foundation · 2013Article
- CMR-determined scar volume: predictive for ventricular tachycardias?The international journal of cardiovascular imaging · 2011Article
- Health care utilisation after defibrillator implantation for primary prevention according to the guidelines in 2 Dutch academic medical centres.Netherlands heart journal : monthly journal of the Netherlands Society of Cardiology and the Netherlands Heart Foundation · 2011Article
- Primary prevention with the ICD in clinical practice: not as straightforward as the guidelines suggest?Netherlands heart journal : monthly journal of the Netherlands Society of Cardiology and the Netherlands Heart Foundation · 2009Article
- Clinical implementation of guidelines for cardioverter defibrillator implantation: lost in translation?Netherlands heart journal : monthly journal of the Netherlands Society of Cardiology and the Netherlands Heart Foundation · 2007Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeGuidelines for implantation of cardioverter defibrillators (ICD) are increasingly including indications for primary prevention of sudden cardiac death in high-risk groups, where ICDs were traditionally implanted for secondary prevention. We performed a single-centre audit to evaluate adherence to the recent Dutch guidelines.
methodsAll 1886 patients visiting a large regional Dutch teaching hospital (attending 1.8 to 2.0% of the Dutch population) in November 2005 were screened using the recently updated Dutch guidelines. Patients fulfilling these criteria were categorised as having an ICD indication for primary or secondary prevention.
results135 patients had an indication for ICD, 19 of whom had one or received one. Of the remaining 116 patients, 14 were 'new' to the department of cardiology. The 102 'known' patients had 466 doctor-patient contacts in the previous year, which averages 4.57 cardiology contacts per patient per year. Patients were more likely to receive an ICD for the secondary prevention of SCD (10/11, 91%) than for primary prevention (9/124, 7%).
conclusionIn a large regional teaching hospital in the Netherlands, only a small proportion of patients eligible for ICD implantation actually receive one. Cardiologists tend to implant ICDs for secondary prevention of SCD. The low ICD implantation rate for primary prevention of SCD may relate to logistics (e.g. permission to implant ICDs, the presence of an electrophysiology lab) or the perceived low cost-benefit ratio. Our results indicate that once the substantial backlog (13,500 ICDs) has been addressed, the annual implantation of new ICDs should rise from the current 125 to at least 510 per million inhabitants per year in the Netherlands. (Neth Heart J 2007;15:129-32.).
Identifiers