Evidence map›Paper›PMID 17500007›Full record

ArticleJournal of the American Society for Mass Spectrometry2007

Analysis of protein mixtures by electrospray mass spectrometry: effects of conformation and desolvation behavior on the signal intensities of hemoglobin subunits.

Mark C Kuprowski, Brian L Boys, Lars Konermann

Abstract read
PubMed Publisher
In one paragraph

Article in Journal of the American Society for Mass Spectrometry, 2007. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.

0numbers the graph read from it
0cells of the map it votes in
12citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

12 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Native top-down mass spectrometry for the structural characterization of human hemoglobin.European journal of mass spectrometry (Chichester, England) · 2015
    Article
  5. Article
  6. Article
  7. Gas-phase ions of human hemoglobin A, F, and S.Journal of the American Society for Mass Spectrometry · 2011
    Article
  8. Article
  9. Article
  10. Article
  11. Probing hemoglobin structure by means of traveling-wave ion mobility mass spectrometry.Journal of the American Society for Mass Spectrometry · 2009
    Article
  12. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Mark C KuprowskiDepartment of Chemistry, The University of Western Ontario, London, Ontario, Canada.
Brian L Boys
Lars Konermann

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The determination of solution-phase protein concentration ratios based on ESI-MS intensity ratios is not always straightforward. For example, equimolar mixtures of hemoglobin alpha- and beta-subunits consistently result in much higher peak intensities for the alpha-chain. The current work explores the origin of this effect. Under mildly acidic conditions (pH 3.4) alpha-globin is extensively unfolded, whereas beta-globin retains residual structure. Because of its greater nonpolar character, the more unfolded alpha-subunit can more effectively compete for charge. This leads to suppression of beta-globin signals under conditions where the protein ion yield is limited by the charge concentration on the initially formed ESI droplets. More balanced intensities are observed when operating under charge excess conditions and/or in a solvent environment where both proteins are unfolded to a similar degree (pH 2.2). However, even in these cases the overall alpha-globin peak intensity is still twice as high as that of the beta-subunit. The persistent imbalance under these conditions originates from the different declustering behaviors of the two proteins. A considerable fraction of beta-globin undergoes incomplete desolvation during ESI, thereby reducing the intensity of bare [beta + zH](z+) ions. When including the contributions of incompletely desolvated species, the overall alpha:beta ion intensity ratio is close to unity. The alpha:beta intensity imbalance can also be eliminated by a strongly elevated declustering potential in the ion sampling interface. In conclusion, important factors that have to be considered for the ESI-MS analysis of protein mixtures are (1) conformational effects, resulting in differential surface activities, and (2) dissimilarities in the protein desolvation behavior.

Indexed as

Complex MixturesHemoglobinsHydrogen-Ion ConcentrationProtein ConformationProtein SubunitsSolventsSpectrometry, Mass, Electrospray IonizationComplex MixturesHemoglobinsProtein SubunitsSolvents

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.