Evidence map›Paper›PMID 17483864›Full record

ArticleOsteoporosis international : a journal established as result of cooperation between the European Foundation for Osteoporosis and the National Osteoporosis Foundation of the USA2007

Precision and accuracy of measuring changes in bone mineral density by dual-energy X-ray absorptiometry.

P Tothill, W J Hannan

Abstract read
PubMed Publisher
In one paragraph

Article in Osteoporosis international : a journal established as result of cooperation between the European Foundation for Osteoporosis and the National Osteoporosis Foundation of the USA, 2007. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 17 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
17citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

17 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Trial
  3. Effects of whole body vibration on bone mineral density and falls: results of the randomized controlled ELVIS study with postmenopausal women.Osteoporosis international : a journal established as result of cooperation between the European Foundation for Osteoporosis and the National Osteoporosis Foundation of the USA · 2011
    Trial
  4. Effects of romosozumab on the peripheral and axial skeleton in postmenopausal women at high fracture risk: real-world evidence from DXA and HR-pQCT data.Osteoporosis international : a journal established as result of cooperation between the European Foundation for Osteoporosis and the National Osteoporosis Foundation of the USA · 2026
    Article
  5. Article
  6. Observational
  7. Article
  8. Article
  9. Article
  10. Review
  11. Article
  12. Article
  13. The measurement of bone mineral density of bilateral proximal humeri using DXA in patients with unilateral rotator cuff tear.Osteoporosis international : a journal established as result of cooperation between the European Foundation for Osteoporosis and the National Osteoporosis Foundation of the USA · 2014
    Article
  14. Article
  15. Article
  16. Review
  17. Comment on Tothill and Hannan: precision and accuracy of measuring changes in bone mineral density by dual-energy X-ray absorptiometry.Osteoporosis international : a journal established as result of cooperation between the European Foundation for Osteoporosis and the National Osteoporosis Foundation of the USA · 2008
    Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

2 authors.

P TothillDepartment of Medical Physics, Western General Hospital, Edinburgh EH4 2XU, UK. peter.tothill@ed.ac.uk
W J Hannan

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

unlabelledLong-term precision of two Hologic DXA scanners was derived from repeated clinical measurements. With typical subjects, the long-term coefficients of variation were about twice the short-term. The accuracy of the measurement of changes was compromised by anomalies, but this did not seriously affect clinical conclusions.

introductionLong-term precision and accuracy of BMD measurements need review.

methodsLong-term precision was examined by selecting, from Hologic databases, subjects who had had four scans over a period of 2 to 5 years and was calculated from the SEE of a regression of BMD against time. Accuracy was assessed from relationships between changes (delta) in BA, BMD and BMC.

resultsFor one group of subjects, the long-term precision was 2.4% for lumbar spine, 2.3% for total hip and 2.7% for femoral neck when expressed as CVs. These values were nearly twice the short-term CVs of 1.3% for spine, 1.2% for total hip and 1.4% for femoral neck. For another group, a negative exponential regression gave a better fit, leading to CVs of 1.3% for the spine, 1.4% for total hip and 2.1% for femoral neck. Significant correlations between deltaBA and deltaBMC were found. These led to an underestimate of deltaBMD in spine and hip by 25%.

conclusionsThe poorer long-term precision for typical patients should be borne in mind in monitoring progress. The underestimate of changes could account for only a part of the underestimation by BMD measurements of the anti-fracture effects of anti-resorptive drugs.

Indexed as

Bone DensityAbsorptiometry, PhotonAdolescentAdultAgedFemaleFemur NeckFollow-Up StudiesHip JointHumansLumbar VertebraeMiddle AgedOsteoporosisPhantoms, ImagingReproducibility of Results

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.