Evidence map›Paper›PMID 17276111›Full record

ArticleJournal of magnetic resonance (San Diego, Calif. : 1997)2007

A parametric approach to spectral-spatial EPR imaging.

Subhojit Som, Lee C Potter, Rizwan Ahmad, Periannan Kuppusamy

Abstract read
In one paragraph

Article in Journal of magnetic resonance (San Diego, Calif. : 1997), 2007. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers.

0numbers the graph read from it
0cells of the map it votes in
14citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

14 citing papers in PubMed.

  1. Article
  2. Article
  3. Implementation of GPU-accelerated back projection for EPR imaging.Journal of X-ray science and technology · 2015
    Article
  4. Article
  5. Article
  6. Dual-scan acquisition for accelerated continuous-wave EPR oximetry.Journal of magnetic resonance (San Diego, Calif. : 1997) · 2012
    Article
  7. Spectral modeling for accelerated pH spectroscopy using EPR.Journal of magnetic resonance (San Diego, Calif. : 1997) · 2012
    Article
  8. Multisite EPR oximetry from multiple quadrature harmonics.Journal of magnetic resonance (San Diego, Calif. : 1997) · 2012
    Article
  9. Article
  10. Digital detection and processing of multiple quadrature harmonics for EPR spectroscopy.Journal of magnetic resonance (San Diego, Calif. : 1997) · 2010
    Article
  11. In vivo multisite oximetry using EPR-NMR coimaging.Journal of magnetic resonance (San Diego, Calif. : 1997) · 2010
    Article
  12. Regularized optimization (RO) reconstruction for oximetric EPR imaging.Journal of magnetic resonance (San Diego, Calif. : 1997) · 2008
    Article
  13. EPR oximetry in three spatial dimensions using sparse spin distribution.Journal of magnetic resonance (San Diego, Calif. : 1997) · 2008
    Article
  14. Estimation of mean and median pO2 values for a composite EPR spectrum.Journal of magnetic resonance (San Diego, Calif. : 1997) · 2008
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Subhojit SomDepartment of Electrical and Computer Engineering, The College of Engineering, The Ohio State University, 2015 Neil Avenue, Columbus, OH 43210, USA.
Lee C Potter
Rizwan Ahmad
Periannan Kuppusamy

Funding

Novel Methods for in Vivo Imaging of Tissue OxygenationR01EB005004 · NIBIB · OHIO STATE UNIVERSITY · PI KUPPUSAMY, PERIANNAN · 2005 to 2008
$1.0M
NIBIB NIH HHS EB005004NIBIB NIH HHS R01 EB005004
6 · The paper itself

Abstract

Continuous wave electron paramagnetic resonance imaging for in vivo mapping of spin distribution and spectral shape requires rapid data acquisition. A spectral-spatial imaging technique is presented that provides an order of magnitude reduction in acquisition time, compared to iterative tomographic reprojection. The proposed approach assumes that spectral shapes in the sample are well-approximated by members from a parametric family of functions. A model is developed for the spectra measured with magnetic field modulation. Parameters defining the spin distribution and spectral shapes are then determined directly from the measurements using maximum a posteriori probability estimation. The approach does not suffer approximation error from limited sweep width of the main magnetic field and explicitly incorporates the variability in signal-to-noise ratio versus strength of magnetic field gradient. The processing technique is experimentally demonstrated on a one-dimensional phantom containing a nitroxide spin label with constant g-factor. Using an L-band EPR spectrometer, spectral shapes and spin distribution are accurately recovered from two projections and a spectral window which is comparable to the maximum linewidth of the sample.

Indexed as

AlgorithmsArtificial IntelligenceElectron Spin Resonance SpectroscopyImage EnhancementImage Interpretation, Computer-AssistedPattern Recognition, AutomatedSpin LabelsSpin Labels

Identifiers

PMID17276111
PMCPMC2020527

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.