Evidence map›Paper›PMID 17230546›Full record

ArticleSynapse (New York, N.Y.)2007

PET imaging of neurokinin-1 receptors with [(18)F]SPA-RQ in human subjects: assessment of reference tissue models and their test-retest reproducibility.

Fumihiko Yasuno, Sandra M Sanabria, Donald Burns, Richard J Hargreaves, Subroto Ghose, Masanori Ichise, Frederick T Chin, Cheryl L Morse, Victor W Pike, Robert B Innis

Abstract read
In one paragraph

Article in Synapse (New York, N.Y.), 2007. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Up-and-coming Radiotracers for Imaging Pain Generators.Seminars in musculoskeletal radiology · 2023
    Article
  2. Dynamic interactions between plasma IL-1 family cytokines and central endogenous opioid neurotransmitter function in humans.Neuropsychopharmacology : official publication of the American College of Neuropsychopharmacology · 2015
    Article
  3. Article
  4. Article
  5. Article
  6. Review
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Fumihiko YasunoMolecular Imaging Branch, National Institute of Mental Health, Bethesda, Maryland 20892, USA. yasunof@mail.nih.gov
Sandra M Sanabria
Donald Burns
Richard J Hargreaves
Subroto Ghose
Masanori Ichise
Frederick T Chin
Cheryl L Morse
Victor W Pike
Robert B Innis

Funding

Translational Evaluation Of PET RadiotracersZIAMH002795 · NIMH · NATIONAL INSTITUTE OF MENTAL HEALTH · PI INNIS, ROBERT · 2009 to 2025
$32.0M
PET Radiopharmaceutical SciencesZ01MH002793 · NIMH · NATIONAL INSTITUTE OF MENTAL HEALTH · PI PIKE, VICTOR W · 2002 to 2008
$7.4M
Clinical Evaluation of PET RadiotracersZ01MH002852 · NIMH · NATIONAL INSTITUTE OF MENTAL HEALTH · PI INNIS, ROBERT · 2005 to 2008
$4.4M
Preclinical Evaluation Of PET RadiotracersZ01MH002795 · NIMH · NATIONAL INSTITUTE OF MENTAL HEALTH · PI INNIS, ROBERT · 2002 to 2008
$3.2M
Intramural NIH HHS Z01 MH002852Intramural NIH HHS ZIA MH002795NIMH NIH HHS Z01-MH-002852-01
6 · The paper itself

Abstract

[(18)F]SPA-RQ (substance P antagonist receptor quantifier) labels the substance P-preferring (NK(1)) receptor in human brain. A prior study showed that [(18)F]SPA-RQ brain uptake can be quantified with a reference tissue method and thereby avoid invasive blood sampling. The purposes of this study were to compare three different reference tissue methods and to assess test-retest reproducibility. Eight healthy subjects underwent two [(18)F]SPA-RQ scans. We calculated the binding potential (BP), which is proportional to receptor density, from both regional volume of interest and voxel-wise data. We compared three reference tissue methods: simplified reference tissue model, multilinear reference tissue model (MRTM), and its two-parameter version (MRTM2). The three methods generated equivalent values of regional BP, but MRTM2 was the most resistant to noise. Temporally stable values of BP were obtained with 240 min of imaging data. MRTM2 had excellent test-retest reproducibility, with high reliability (intraclass correlation > 0.9) and low variability (< 10%). In addition to regional volume of interest analysis, we also created parametric images of BP, variability, and reliability based on voxel-wise time-activity data. The reproducibility of parametric BP was also good, with variability < 20% and reliability > 0.7 in gray matter regions. In conclusion, a two-parameter reference tissue method (MRTM2) provided reproducible and reliable measurements of [(18)F]SPA-RQ brain uptake using 240 min of both regional and voxel-wise data.

Indexed as

Brain MappingPositron-Emission TomographyAdultBrainFemaleFluorine RadioisotopesHumansImage Interpretation, Computer-AssistedLinear ModelsMaleMiddle AgedPiperidinesReceptors, Neurokinin-1Reference ValuesReproducibility of ResultsSensitivity and Specificity(2-fluoromethoxy-5-(5-trifluoromethyltetrazol-1-yl)benzyl)(2-phenylpiperidin-3-yl)amineFluorine RadioisotopesPiperidinesReceptors, Neurokinin-1Tetrazoles

Identifiers

PMID17230546
PMCPMC4104790

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.