Evidence map›Paper›PMID 17134510›Full record

ArticleJournal of inflammation (London, England)2006

Detection of cytokine protein expression in mouse lung homogenates using suspension bead array.

Eric McDuffie, Leslie Obert, Jonathan Chupka, Robert Sigler

Open access · goldAbstract read
In one paragraph

Article in Journal of inflammation (London, England), 2006. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
0.7field-weighted citation impact, top 32% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed, 17 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Eric McDuffieDrug Safety Evaluation Department, Esperion, a Division of Pfizer Research and Development, Ann Arbor, Michigan, 48108 USA.
Leslie Obert *Worldwide Safety Sciences Department, Pathology Section, Pfizer Research and Development, Ann Arbor, Michigan, 48105 USA.
Jonathan Chupka *Drug Safety Evaluation Department, Esperion, a Division of Pfizer Research and Development, Ann Arbor, Michigan, 48108 USA.
Robert SiglerDrug Safety Evaluation Department, Esperion, a Division of Pfizer Research and Development, Ann Arbor, Michigan, 48108 USA.
Pfizer (United States) · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe objective for this present study was to determine whether or not suspension bead array is a feasible method to detect changes in cytokine protein expression in mouse lung tissue homogenates. Here, we report on suspension bead array as a feasible method for detection of lipopolysaccharide (LPS)-evoked changes in cytokine protein expression in mouse lung tissue homogenates. MATERIALS AND

methodsMice were treated (0.2 ml, intraperitoneal, i.p.) with phosphate buffered saline (PBS) or LPS (0.25 mg/ml) and sacrificed at either 2- or 24-hours post treatment. Formalin-fixed and paraffin-embedded lung sections were evaluated by light microscopy. Flash frozen lung tissues were homogenized for measurement of various cytokine protein expression levels using suspension bead array, antibody array and ELISA. Comparison between groups was performed using a Wilcoxon signed rank test.

resultsPulmonary perivascular edema and an accumulation of mixed cell infiltrates within blood and lymphatic vessels, as well as in the adjacent interstitium, were present at both 2- and 24-hours following LPS treatment. A minimal increase in the number of alveolar macrophages was also observed in the 24-hour LPS-treated mice only. The suspension bead array assay revealed statistically significant increases in mouse lung tissue homogenate levels of interleukin-6 (IL-6) and granulocyte/macrophage colony-stimulating factor (GM-CSF) proteins and a decrease in IL-2 protein at 24-hours post LPS-treatment only. Similar cytokine protein expression patterns were observed using antibody array. Significantly increased IL-6 protein expression levels were also detected using ELISA, which correlated with the suspension bead array data.

conclusionThe present study shows that suspension bead array is a feasible method to detect changes in cytokine protein expression in mouse lung tissue homogenates.

Identifiers

PMID17134510
PMCPMC1681346
OpenAlexW2108906318

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.