ArticleNeurocritical care2006
A device for fast mechanical clot retrieval from intracranial arteries (Phenox clot retriever).
Article in Neurocritical care, 2006. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 17 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
17 citing papers in PubMed.
- What You Always Wanted to Know about Endovascular Therapy in Acute Ischemic Stroke but Never Dared to Ask: A Comprehensive Review.Reviews in cardiovascular medicine · 2022Review
- A short history of thrombectomy - Procedure and success analysis of different endovascular stroke treatment techniques.Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2021Article
- Clinical and Angiographic Outcomes with the Combined Local Aspiration and Retriever in the North American Solitaire Stent-Retriever Acute Stroke (NASA) Registry.Interventional neurology · 2018Article
- Neurointerventional treatment of amphetamine-induced acute occlusion of the middle cerebral artery by intracranial balloon angioplasty.Clinical neuroradiology · 2013Article
- Endovascular thrombectomy following acute ischemic stroke: a single-center case series and critical review of the literature.Brain sciences · 2013Article
- Intracranial thrombectomy using the Solitaire stent: a historical vignette.Journal of neurointerventional surgery · 2012Article
- Beyond the time window of intravenous thrombolysis: standing by or by stenting?Interventional neurology · 2012Review
- The phenox clot retriever as part of a multimodal mechanical thrombectomy approach in acute ischemic stroke: single center experience in 56 patients.TheScientificWorldJournal · 2012Article
- Intra-arterial treatment methods in acute stroke therapy.Frontiers in neurology · 2011Article
- Recanalization therapy for acute ischemic stroke, part 2: mechanical intra-arterial technologies.Neurosurgical review · 2011Review
- Treatment of acute middle cerebral artery occlusion with a Solitaire AB stent: preliminary experience.The British journal of radiology · 2010Article
- Current recommendations for endovascular interventions in the treatment of ischemic stroke.Current atherosclerosis reports · 2010Article
- In vivo evaluation of the Phenox CRC mechanical thrombectomy device in a swine model of acute vessel occlusion.AJNR. American journal of neuroradiology · 2010Article
- [Mechanical recanalization].Der Radiologe · 2009Review
- Endovascular approaches to acute stroke, part 1: Drugs, devices, and data.AJNR. American journal of neuroradiology · 2009Review
- Acute stroke therapy 1981-2009.Klinische Neuroradiologie · 2009Review
- Comparative in vitro study of five mechanical embolectomy systems: effectiveness of clot removal and risk of distal embolization.Neuroradiology · 2008Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
introductionTo describe a new device meant for rapid endovascular thrombectomy of intracranial arteries of various sizes and its first clinical use.
methodsA device with oriented microfilaments was constructed that consists of a core wires compound surrounded by a dense palisade of perpendicular-oriented stiff polyamid microfilaments (phenox clot retriever). The device is introduced into the target vessel through a 0.021- or 0.027-inch microcatheter, deployed distally to the thrombus, and slowly pulled back under continuous aspiration via the guiding catheter.
resultsThe clinical use of the phenox clot retriever in two successive patients is described. Case 1: In a 78-year-old patient with acute posterior circulation ischemia not eligible for intravenous or intraarterial thrombolysis, endovascular recanalization of the occluded left V4 segment was possible using the phenox clot retriever within a few minutes. Case 2: A 70-year-old patient presented after the sudden onset of a left upper extremity paresis 1 day after abdominal surgery. Angiography revealed a thromboembolic occlusion of two cortical branches of the right middle cerebral artery. The rolandic artery was recanalized by a single passage of the phenox clot retriever, with complete neurological recovery.
conclusionThe phenox clot retriever, a flexible microfilament pattern, might be a useful supplement to the repertoire of currently available devices for endovascular intracranial thrombectomy.
Indexed as
Identifiers
17099260What OpenQuestion holds
Registered trials