ArticleJournal of clinical microbiology2007
Quantitative detection of plasma human immunodeficiency virus type 2 subtype A RNA by the Nuclisens EasyQ Assay (version 1.1).
Article in Journal of clinical microbiology, 2007. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
9 citing papers in PubMed, 23 citations in OpenAlex.
- HIV treatment response among female sex workers participating in a treatment as prevention demonstration project in Cotonou, Benin.PloS one · 2020Article
- New sensitive one-step real-time duplex PCR method for group A and B HIV-2 RNA load.Journal of clinical microbiology · 2014Article
- An international collaboration to standardize HIV-2 viral load assays: results from the 2009 ACHI(E)V(2E) quality control study.Journal of clinical microbiology · 2011Article
- RNA versus DNA (NucliSENS EasyQ HIV-1 v1.2 versus Amplicor HIV-1 DNA test v1.5) for early diagnosis of HIV-1 infection in infants in Senegal.Journal of clinical microbiology · 2011Article
- Update on human immunodeficiency virus (HIV)-2 infection.Clinical infectious diseases : an official publication of the Infectious Diseases Society of America · 2011Review
- HIV-2 diagnosis and quantification in high-risk patients.AIDS research and therapy · 2008Article
- Quality control assessment of human immunodeficiency virus type 2 (HIV-2) viral load quantification assays: results from an international collaboration on HIV-2 infection in 2006.Journal of clinical microbiology · 2008Article
- Transmitted drug resistance, selection of resistance mutations and moderate antiretroviral efficacy in HIV-2: analysis of the HIV-2 Belgium and Luxembourg database.BMC infectious diseases · 2008Article
- Comparison of viro-immunological marker changes between HIV-1 and HIV-2-infected patients in France.AIDS (London, England) · 2008Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
No commercial viral load assay has yet been approved for use for measurement of human immunodeficiency virus type 2 (HIV-2) RNA levels in plasma. We assessed the performance of the NucliSens EasyQ (version 1.1) assay (EasyQ; bioMérieux, Boxtel, The Netherlands) to quantify HIV-2 viremia. A viral stock was prepared from an HIV-2 (subtype A)-infected patient. Culture supernatant was subjected to viral particle counting by electron microscopy. Serial dilutions of the viral stock were made in HIV-negative plasma and were used to test EasyQ for its sensitivity, linearity, and reproducibility. RNA was quantified by the NucliSens EasyQ (version 1.1) assay. Plasma samples from 75 HIV-2-infected patients were further tested. EasyQ was able to quantify HIV-2 RNA in a reproducible manner. Overall, estimates of the number of HIV-2 RNA copies/ml obtained with EasyQ were lower than those obtained by electron microscopy; however, the differences were always less than 0.7 log (mean, 0.55 +/- 0.19 log(10)). The assay showed good linearity (r(2) = 0.964; P < 0.0001). The agreement between both measures was assessed by use of a Bland-Altman plot; the narrow limits (0.158 to 0.952), defined as the mean difference +/- 2 standard deviations, indicated good agreement. The reproducibility was also good, since the between-run coefficients of variation were 1.49, 3.60, and 12.25% for samples containing 6.30, 4.30, and 2.30 log(10) HIV-2 RNA copies/ml, respectively. HIV-2 RNA was detected in 34 of 75 (45%) plasma specimens (mean, 2.72 log RNA copies/ml; range, 1.74 to 4.11 log RNA copies/ml); the rest of the specimens were considered to have undetectable viremia. A negative correlation was found between the number of HIV-2 RNA copies/ml and CD4 counts. In summary, EasyQ was shown to be reliable for the measurement of plasma HIV-2 subtype A RNA levels and may be a feasible tool for routine clinical monitoring of HIV-2 subtype A-infected patients.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.