Evidence map›Paper›PMID 17041245›Full record

ArticleThe Annals of occupational hygiene2007

Physical collection efficiency of filter materials for bacteria and viruses.

Nancy Clark Burton, Sergey A Grinshpun, Tiina Reponen

Abstract read
In one paragraph

Article in The Annals of occupational hygiene, 2007. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 54 papers.

0numbers the graph read from it
0cells of the map it votes in
54citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

54 citing papers in PubMed.

  1. Trial
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Nanofibrous filters: A promising solution for the efficient capture of polydisperse viral aerosols.Aerosol science and technology : the journal of the American Association for Aerosol Research · 2025
    Article
  9. Article
  10. Article
  11. Review
  12. Article
  13. Article
  14. Mechanisms, Techniques and Devices of Airborne Virus Detection: A Review.International journal of environmental research and public health · 2023
    Review
  15. Article
  16. Fast Air-to-Liquid Sampler Detects Surges in SARS-CoV-2 Aerosol Levels in Hospital Rooms.International journal of environmental research and public health · 2022
    Article
  17. Article
  18. The size and culturability of patient-generated SARS-CoV-2 aerosol.Journal of exposure science & environmental epidemiology · 2022
    Article
  19. Review
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Nancy Clark BurtonCenters for Disease Control and Prevention, National Institute for Occupational Safety and Health 4676 Columbia Parkway, MS R-11, Cincinnati, OH 45226, USA. NBurton@cdc.gov
Sergey A Grinshpun
Tiina Reponen

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The purpose of this study was to determine the physical collection efficiency of commercially available filters for collecting airborne bacteria, viruses, and other particles in the 10-900 nm (nanometer) size range. Laboratory experiments with various polytetrafluoroethylene (PTFE), polycarbonate (PC) and gelatin filters in conjunction with Button Inhalable samplers and three-piece cassettes were undertaken. Both biological and non-biological test aerosols were used: Bacillus atrophaeus, MS2, polystyrene latex (PSL), and sodium chloride (NaCl). The B.atrophaeus endospores had an aerodynamic diameter of 900 nm, whereas MS2 virion particles ranged from 10 to 80 nm. Monodisperse 350 nm PSL particles were used as this size was believed to have the lowest filtration efficiency. NaCl solution (1% weight by volume) was used to create a polydisperse aerosol in the 10-600 nm range. The physical collection efficiency was determined by measuring particle concentrations size-selectively upstream and downstream of the filters. The PTFE and gelatin filters showed excellent collection efficiency (>93%) for all of the test particles. The PC filters showed lower collection efficiency for small particles especially <100 nm. Among the tested filters, the lowest collection efficiencies, 49 and 22%, were observed for 1 and 3-microm pore size PC filters at the particle sizes of 47 and 63 nm, respectively. The results indicate that the effect of filter material is more significant for the size range of single virions than for bacteria. The effect of filter loading was examined by exposing filters to mixtures of PSL particles, which aimed at mimicking typical indoor dust levels and size distributions. A 4-h loading did not cause significant change in the physical collection efficiency of the tested filters.

Indexed as

Air MicrobiologyBacteriaVirusesAir PollutantsDustEnvironmental ExposureEnvironmental MonitoringEquipment DesignFiltrationGelatinParticle SizePolycarboxylate CementPolystyrenesPolytetrafluoroethyleneAir PollutantsDustGelatinpolycarbonatePolycarboxylate CementPolystyrenesPolytetrafluoroethylenestyrofoam

Identifiers

PMID17041245
PMCPMC7187796

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked