ArticleCritical care (London, England)2006
Accuracy and feasibility of point-of-care and continuous blood glucose analysis in critically ill ICU patients.
Article in Critical care (London, England), 2006. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 61 papers, 2 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
61 citing papers in PubMed, 2 syntheses or guidelines pooled it, 163 citations in OpenAlex.
- Continuous Glucose Monitors and Automated Insulin Dosing Systems in the Hospital Consensus Guideline.Journal of diabetes science and technology · 2020Guideline
- Accuracy of blood-glucose measurements using glucose meters and arterial blood gas analyzers in critically ill adult patients: systematic review.Critical care (London, England) · 2013Pooled it
- Accuracy and reliability of a subcutaneous continuous glucose monitoring device in critically ill patients.Journal of clinical monitoring and computing · 2018Trial
- Accuracy of 2 Different Continuous Glucose Monitoring Systems in Patients Undergoing Cardiac Surgery.Journal of diabetes science and technology · 2017Trial
- Feasibility of fully automated closed-loop glucose control using continuous subcutaneous glucose measurements in critical illness: a randomized controlled trial.Critical care (London, England) · 2013Trial
- Evaluation of a continuous blood glucose monitoring system using central venous microdialysis.Journal of diabetes science and technology · 2012Trial
- Glycemic variability and glucose complexity in critically ill patients: a retrospective analysis of continuous glucose monitoring data.Critical care (London, England) · 2012Trial
- Continuous glucose monitoring system in a rural intensive care unit: a pilot study evaluating accuracy and acceptance.Journal of diabetes science and technology · 2010Trial
- Real-time continuous glucose monitoring in critically ill patients: a prospective randomized trial.Diabetes care · 2010Trial
- Continuous interstitial glucose monitoring in diabetic and non-diabetic critically ill patients is simple and accurate: comparison with venous, arterial and capillary glucose measurements.Acta diabetologica · 2025Observational
- Accuracy of continuous glucose monitoring systems in intensive care unit patients: a scoping review.Intensive care medicine · 2024Article
- Low preoperative hemoglobin A1c level is a predictor of perioperative infectious complications after esophagectomy: A retrospective, single-center study.Global health & medicine · 2024Article
- Effects of Glycemic Variability in Critically Ill Patients with Coronavirus Disease 2019: A Retrospective Observational Study.Indian journal of critical care medicine : peer-reviewed, official publication of Indian Society of Critical Care Medicine · 2024Article
- Comparing the accuracy of point-of-care with laboratory (capillary, venous, and arterial) blood glucose levels in critically ill patients with and without shock.BMC research notes · 2022Article
- Continuous Glucose Monitoring in the Hospital.Endocrinology and metabolism (Seoul, Korea) · 2021Review
- Diabetes Technology Update: Use of Insulin Pumps and Continuous Glucose Monitoring in the Hospital.Diabetes care · 2018Review
- A prolonged run-in period of standard subcutaneous microdialysis ameliorates quality of interstitial glucose signal in patients after major cardiac surgery.Scientific reports · 2018Article
- A comparative assessment of the glucose monitor (SD Codefree) and auto analyzer (BT-3000) in measuring blood glucose concentration among diabetic patients.BMC research notes · 2017Article
- Inpatient Continuous Glucose Monitoring and Glycemic Outcomes.Journal of diabetes science and technology · 2017Review
- The Clinical Benefits and Accuracy of Continuous Glucose Monitoring Systems in Critically Ill Patients-A Systematic Scoping Review.Sensors (Basel, Switzerland) · 2017Article
1 more citing papers are in PubMed but not listed here.
Corrections and comments
- Commented on by
Authors and funding
8 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
introductionTo obtain strict glucose regulation, an accurate and feasible bedside glucometry method is essential. We evaluated three different types of point-of-care glucometry in seriously ill intensive care unit (ICU) patients. The study was performed as a single-centre, prospective, observational study in a 12-bed medical ICU of a university hospital.
methodsPatients with an expected ICU stay of more than 48 hours were included. Because the reference laboratory delivers glucose values after approximately 30 to 60 minutes, which is too slow to use in a glucose regulation protocol and for calibration of the subcutaneous continuous glucose monitoring system (CGMS) (CGMS System Gold), we first validated the ICU-based blood gas/glucose analyser ABL715 (part 1 of the study). Subsequently, part 2 was performed: after inserting (and calibrating) the subcutaneous CGMS, heparinised arterial blood samples were drawn from an arterial line every 6 hours and analysed on both the Precision PCx point-of-care meter using test strips and on the blood gas/glucose analyser ABL715. CGMS glucose data were downloaded after 24 to 72 hours. The results of the paired measurements were analysed as a scatter plot by the method of Bland and Altman and were expressed as a correlation coefficient.
resultsPart 1: Four hundred and twenty-four blood samples were drawn from 45 critically ill ICU patients. The ICU-based blood gas/glucose analyser ABL715 provided a good estimate of conventional laboratory glucose assessment: the correlation coefficient was 0.95. In the Clarke error grid, 96.8% of the paired measurements were in the clinically acceptable zones A and B. Part 2: One hundred sixty-five paired samples were drawn from 19 ICU patients. The Precision PCx point-of-care meter showed a correlation coefficient of 0.89. Ninety-eight point seven percent of measurements were within zones A and B. The correlation coefficient for the subcutaneous CGMS System Gold was 0.89. One hundred percent of measurements were within zones A and B.
conclusionThe ICU-based blood glucose analyser ABL715 is a rapid and accurate alternative for laboratory glucose determination and can serve as a standard for ICU blood glucose measurements. The Precision PCx is a good alternative, but feasibility may be limited because of the blood sample handling. The subcutaneous CGMS System Gold is promising, but real-time glucose level reporting is necessary before it can be of clinical use in the ICU. When implementing a glucose-insulin algorithm in patient care or research, one should realise that the absolute glucose level may differ systematically among various measuring methods, influencing targeted glucose levels.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.