Evidence map›Paper›PMID 16928152›Full record

ArticleClinical pharmacokinetics2006

Patient characteristics influencing ciclosporin pharmacokinetics and accurate Bayesian estimation of ciclosporin exposure in heart, lung and kidney transplant patients.

Franck Saint-Marcoux, Pierre Marquet, Evelyne Jacqz-Aigrain, Nicole Bernard, Philippe Thiry, Yann Le Meur, Annick Rousseau

Abstract read
PubMed Publisher
In one paragraph

Article in Clinical pharmacokinetics, 2006. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers.

0numbers the graph read from it
0cells of the map it votes in
13citing papers in PubMed
1.9field-weighted citation impact, top 17% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

13 citing papers in PubMed, 39 citations in OpenAlex.

  1. Trial
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Review
  8. Article
  9. Article
  10. Article
  11. Review
  12. Article
  13. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 3 institutions in 2 countries.

Franck Saint-MarcouxDepartment of Pharmacology and Toxicology, University Hospital, Limoges, France.
Pierre Marquet
Evelyne Jacqz-Aigrain
Nicole Bernard
Philippe Thiry
Yann Le Meur
Annick Rousseau
Université de Limoges · FRErasmus Hospital · BEHôpital Foch · FR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

BACKGROUND AND

objectivesPopulation pharmacokinetic studies of ciclosporin microemulsion are needed to identify the individual factors influencing ciclosporin pharmacokinetic variability in transplant patients and to design efficient tools for the accurate estimation of ciclosporin overall exposure (area under the plasma concentration-time curve from 0 to 12 hours [AUC12]). In the present retrospective study, a large database of heart, lung (with or without cystic fibrosis) and kidney (both adult and paediatric) transplant patients receiving ciclosporin microemulsion was analysed with the aims of (i) building a population pharmacokinetic model and finding the main covariates linked with ciclosporin microemulsion pharmacokinetic parameters; and (ii) developing a maximum a posteriori probability Bayesian estimator (MAP-BE) to estimate ciclosporin microemulsion pharmacokinetic parameters using a limited-sampling strategy.

methods3,072 concentration data from 147 patients (i.e. 309 full pharmacokinetic profiles) were analysed using the nonlinear mixed-effects model program NONMEM. The influence of numerous covariates was tested, and the final model was validated by data splitting. For Bayesian estimation, the best limited-sampling strategy was determined based on the D-optimality criterion, and validation performed in an independent group of 60 patients.

resultsThe pharmacokinetics of ciclosporin microemulsion were accurately described by a two-compartment model with Erlang distribution for the absorption process. The type of graft and post-transplantation period were identified as significant sources of variability of the absorption parameter. Both apparent volume of the central compartment after oral administration (V1/F) and apparent oral clearance (CL/F) increased with bodyweight. The best limited-sampling strategy for Bayesian estimation was 0 hour, 1 hour and 3 hour post-dose, providing accurate estimation of ciclosporin microemulsion AUC12 in all patients of the test group, with a mean bias of 2.0 +/- 10.5% (range: -19.1% to -21.4% and 95% CI -0.6, +4.7).

conclusionPopulation pharmacokinetic analysis of ciclosporin microemulsion in allograft transplants resulted in the design of a new pharmacokinetic model for ciclosporin microemulsion, identification of significant covariates and the design of an accurate MAP-BE based on three blood concentrations and these covariates.

Indexed as

Heart TransplantationKidney TransplantationLung TransplantationModels, BiologicalAdolescentAdultAgedBayes TheoremChildChild, PreschoolCyclosporineEmulsionsFemaleHumansImmunosuppressive AgentsInfantCyclosporineEmulsionsImmunosuppressive Agents

Identifiers

PMID16928152
OpenAlexW1976805469

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.