Evidence map›Paper›PMID 16844757›Full record

ArticleBiophysical journal2006

Application of surface plasmon coupled emission to study of muscle.

J Borejdo, Z Gryczynski, N Calander, P Muthu, I Gryczynski

Abstract read
In one paragraph

Article in Biophysical journal, 2006. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 16 papers.

0numbers the graph read from it
0cells of the map it votes in
16citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

16 citing papers in PubMed.

  1. Hyperbolic polariton-coupled emission optical microscopy.Nanophotonics (Berlin, Germany) · 2025
    Article
  2. Article
  3. Surface plasmon-coupled emission imaging for biological applications.Analytical and bioanalytical chemistry · 2020
    Review
  4. Surface plasmon-assisted microscope.Journal of biomedical optics · 2018
    Article
  5. Article
  6. Article
  7. Article
  8. Review
  9. Article
  10. Article
  11. Article
  12. Plasmon-controlled fluorescence towards high-sensitivity optical sensing.Advances in biochemical engineering/biotechnology · 2009
    Review
  13. Article
  14. Article
  15. Article
  16. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

J BorejdoDepartment of Molecular Biology and Immunology, University of North Texas Health Science Center, Fort Worth, Texas 76107, USA. jborejo@hsc.unt.edu
Z Gryczynski
N Calander
P Muthu
I Gryczynski

Funding

Rotation of Single Cross-Bridge in Skeletal Muscle FiberR01AR048622 · NIAMS · UNIVERSITY OF NORTH TEXAS HLTH SCI CTR · PI BOREJDO, JULIAN · 2003 to 2007
$870k
SPCE Imaging MicroscopyR33CA114460 · NCI · UNIVERSITY OF NORTH TEXAS HLTH SCI CTR · PI GRYCZYNSKI, IGNACY · 2005 to 2006
$379k
NCI NIH HHS CA114460NCI NIH HHS R33 CA114460NIAMS NIH HHS R01 AR048622
6 · The paper itself

Abstract

Muscle contraction results from interactions between actin and myosin cross-bridges. Dynamics of this interaction may be quite different in contracting muscle than in vitro because of the molecular crowding. In addition, each cross-bridge of contracting muscle is in a different stage of its mechanochemical cycle, and so temporal measurements are time averages. To avoid complications related to crowding and averaging, it is necessary to follow time behavior of a single cross-bridge in muscle. To be able to do so, it is necessary to collect data from an extremely small volume (an attoliter, 10(-18) liter). We report here on a novel microscopic application of surface plasmon-coupled emission (SPCE), which provides such a volume in a live sample. Muscle is fluorescently labeled and placed on a coverslip coated with a thin layer of noble metal. The laser beam is incident at a surface plasmon resonance (SPR) angle, at which it penetrates the metal layer and illuminates muscle by evanescent wave. The volume from which fluorescence emanates is a product of two near-field factors: the depth of evanescent wave excitation and a distance-dependent coupling of excited fluorophores to the surface plasmons. The fluorescence is quenched at the metal interface (up to approximately 10 nm), which further limits the thickness of the fluorescent volume to approximately 50 nm. The fluorescence is detected through a confocal aperture, which limits the lateral dimensions of the detection volume to approximately 200 nm. The resulting volume is approximately 2 x 10(-18) liter. The method is particularly sensitive to rotational motions because of the strong dependence of the plasmon coupling on the orientation of excited transition dipole. We show that by using a high-numerical-aperture objective (1.65) and high-refractive-index coverslips coated with gold, it is possible to follow rotational motion of 12 actin molecules in muscle with millisecond time resolution.

Indexed as

AnimalsFluorescent DyesIn Vitro TechniquesMicroscopy, ConfocalMuscle ContractionMuscle, SkeletalMyofibrilsSurface Plasmon ResonanceFluorescent Dyes

Identifiers

PMID16844757
PMCPMC1562373

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.