Evidence map›Paper›PMID 16687560›Full record

ArticleAJNR. American journal of neuroradiology2006

Vertebral artery origin stent placement with distal protection: technical and clinical results.

A I Qureshi, J F Kirmani, P Harris-Lane, A A Divani, S Ahmed, A Ebrihimi, A Al Kawi, N Janjua

Registry-linked trialAbstract read
In one paragraph

Article in AJNR. American journal of neuroradiology, 2006. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT03381534 (Safety and Efficacy of Distal Embolic Protection Device in Vertebral Artery Origin Stent Angioplasty), which is not on this map. Cited by 18 papers.

0numbers the graph read from it
0cells of the map it votes in
18citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT03381534 naunknown statusnot on this mapstarted 2017, after this paper: background citation

Safety and Efficacy of Distal Embolic Protection Device in Vertebral Artery Origin Stent Angioplasty :A Prospective, Multicenter, Randomized Controlled Trial

TypeinterventionalSponsorXuanwu Hospital, BeijingRan2017 to 2020Enrolled256ConditionsAdverse EventArmsstenting with EPD, stent assisted angioplasty
3 · Its place in the literature

Who cites it

18 citing papers in PubMed.

  1. Trial
  2. Trial
  3. Review
  4. Article
  5. The resolute Onyx drug eluting stent for neurointervention: A technical series.Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2024
    Article
  6. Endovascular treatment of the vertebral artery origin stenosis by using the closed-cell, self-expandable Carotid Wallstent.Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2020
    Article
  7. Article
  8. Article
  9. Article
  10. Use of Embolic Protection Devices in Peripheral Interventions.Interventional cardiology (London, England) · 2017
    Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Article
  17. Article
  18. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

A I QureshiClinical Trials Division, Zeenat Qureshi Stroke Research Center, Department of Neurology and Neurosciences, New Jersey Medical School, University of Medicine and Dentistry of New Jersey, Newark, NJ, USA.
J F Kirmani
P Harris-Lane
A A Divani
S Ahmed
A Ebrihimi
A Al Kawi
N Janjua

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveTo report the feasibility, safety, and 1-month results of performing stent placement for vertebral origin stenosis with the use of a distal protection device. Distal protection devices have been shown to reduce the number of cerebral emboli and subsequent ischemic events when used as adjuncts to percutaneous carotid intervention; however, one case of the use of a distal protection device for vertebral artery has been reported in the literature.

methodsWe retrospectively determined rates of technical success and 1-month stroke or death associated with stent placement by using distal protection (Filter EX; Boston Scientific, Natick, Mass) in patients with symptomatic vertebral artery origin stenosis. Technical success was defined as successful deployment of distal protection device and stent at target lesion followed by successful retrieval of the device and a final residual stenosis of less than 30%. Other outcomes ascertained included any stroke, death, and semiquantitative assessment of particulate material retained by the filter device.

resultsThe mean age of the 12 treated patients was 68 years (range, 52-88 years) and the group included 9 men and 3 women. The mean percentage of vertebral artery origin stenosis was 71 +/- 6%. Femoral and radial approaches were used in 9 and 3 cases, respectively. Technical success was achieved in 11 of the 12 patients in whom distal protection device placement was attempted. Postprocedure residual stenosis was 5 +/- 4%. Eight devices held macroscopically visible embolic debris (large and small amounts in 3 and 5 devices, respectively). No stroke or death was observed in the 1-month follow-up.

conclusionThe present study demonstrates the feasibility of performing stent placement for vertebral artery origin stenosis by using a distal protection device. Further studies are required to determine the effectiveness of this approach for vertebral artery origin atherosclerosis.

Indexed as

StentsVertebral ArteryAgedAged, 80 and overArterial Occlusive DiseasesFeasibility StudiesFemaleHumansMaleMiddle AgedProsthesis ImplantationRetrospective Studies

Identifiers

PMID16687560
PMCPMC7975752

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.