Evidence map›Paper›PMID 16645740›Full record

ArticleThe Journal of membrane biology2005

Wavelength- and time-dependence of potentiometric non-linear optical signals from styryl dyes.

A C Millard, L Jin, J P Wuskell, D M Boudreau, A Lewis, L M Loew

Abstract read
PubMed Publisher
In one paragraph

Article in The Journal of membrane biology, 2005. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Review
  6. Wide-field and two-photon imaging of brain activity with voltage- and calcium-sensitive dyes.Philosophical transactions of the Royal Society of London. Series B, Biological sciences · 2009
    Review
  7. Article
  8. Imaging membrane potential in dendrites and axons of single neurons.Pflugers Archiv : European journal of physiology · 2006
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

A C MillardCenter for Cell Analysis and Modeling, University of Connecticut Health Center, Farmington, 06030, USA.
L Jin
J P Wuskell
D M Boudreau
A Lewis
L M Loew

Funding

POTENTIOMETRIC DYES AND MEMBRANE PERMEABILITYR01GM035063 · NIGMS · UNIVERSITY OF CONNECTICUT SCH OF MED/DNT · PI LOEW, LESLIE M · 1985 to 2002
$795k
NIGMS NIH HHS GM35063
6 · The paper itself

Abstract

Second harmonic generation (SHG) imaging microscopy is an important emerging technique for biological research, complementing existing one- and two-photon fluorescence (2PF) methods. A non-linear phenomenon employing light from mode-locked Ti:sapphire or fiber-based lasers, SHG results in intrinsic optical sectioning without the need for a confocal aperture. Furthermore, as a second-order process SHG is confined to loci lacking a center of symmetry, a constraint that is readily satisfied by lipid membranes with only one leaflet stained by a dye. Of particular interest is "resonance-enhanced" SHG from styryl dyes in cellular membranes and the possibility that SHG is sensitive to transmembrane potential. We have previously confirmed this, using simultaneous voltage-clamping and non-linear imaging of cells to find that SHG is up to four times more sensitive to potential than fluorescence. In this work, we have extended these results in two directions. First, with a range of wavelengths available from a mode-locked Ti:sapphire laser and a fiber-based laser, we have more fully investigated SHG and 2PF voltage-sensitivity from ANEP and ASTAP chromophores, obtaining SHG sensitivity spectra that are consistent with resonance enhancements. Second, we have modified our system to coordinate the application of voltage-clamp steps with non-linear image acquisition to more precisely characterize the time dependence of SHG and 2PF voltage sensitivity, finding that, at least for some dyes, SHG responds more slowly than fluorescence to changes in transmembrane potential.

Indexed as

Microscopy, Fluorescence, MultiphotonPatch-Clamp TechniquesFiber Optic TechnologyFluorescent DyesLasersPotentiometrySensitivity and SpecificityFluorescent Dyes

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.