SynthesisThe Cochrane database of systematic reviews2006
Aqueous shunts for glaucoma.
Synthesis in The Cochrane database of systematic reviews, 2006. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT00665756 (Comparison of Efficacy Between Silicone Ahmed Glaucoma Valves and Second Trabeculectomy in Glaucoma Patients), which is not on this map. Cited by 37 papers, 11 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Comparison of Efficacy Between Silicone Ahmed Glaucoma Valves and Second Trabeculectomy in Glaucoma Patients
Who cites it
37 citing papers in PubMed, 11 syntheses or guidelines pooled it, 98 citations in OpenAlex.
- Anti-vascular endothelial growth factor for neovascular glaucoma.The Cochrane database of systematic reviews · 2023Pooled it
- Cyclodestructive procedures for refractory glaucoma.The Cochrane database of systematic reviews · 2019Pooled it
- Aqueous shunts for glaucoma.The Cochrane database of systematic reviews · 2017Pooled it
- The treatment methods for post-stroke visual impairment: A systematic review.Brain and behavior · 2017Pooled it
- Device-modified trabeculectomy for glaucoma.The Cochrane database of systematic reviews · 2015Pooled it
- Combined surgery versus cataract surgery alone for eyes with cataract and glaucoma.The Cochrane database of systematic reviews · 2015Pooled it
- Anti-vascular endothelial growth factor for neovascular glaucoma.The Cochrane database of systematic reviews · 2013Pooled it
- Acupuncture for glaucoma.The Cochrane database of systematic reviews · 2013Pooled it
- Medical versus surgical interventions for open angle glaucoma.The Cochrane database of systematic reviews · 2012Pooled it
- Interventions for age-related visual problems in patients with stroke.The Cochrane database of systematic reviews · 2012Pooled it
- Acupuncture for glaucoma.The Cochrane database of systematic reviews · 2007Pooled it
- The Ahmed Baerveldt Comparison Study methodology, baseline patient characteristics, and intraoperative complications.Ophthalmology · 2011Trial
- Article
- Trabeculectomy: Does It Have a Future?Cureus · 2022Review
- Comparison of Outcomes Following Glaucoma Drainage Tube Surgery Between Primary and Secondary Glaucomas, and Between Phakic and Pseudophakic eyes.Asia-Pacific journal of ophthalmology (Philadelphia, Pa.) · 2021Article
- Risk Factors for Failure in Double-Plate Tube Surgery for Refractory Glaucoma: 25 Years Surgical Experience.Clinical ophthalmology (Auckland, N.Z.) · 2021Article
- Anti-fibrotic effects of rosmarinic acid on Tenon's capsule fibroblasts stimulated with TGF-β: therapeutic potential in ocular surgery.Arquivos brasileiros de oftalmologia · 2020Article
- Anti-vascular endothelial growth factor for neovascular glaucoma.The Cochrane database of systematic reviews · 2020Review
- Translating Minimally Invasive Glaucoma Surgery Devices.Clinical and translational science · 2020Review
- "Double scleral tunnel in tandem" technique for glaucoma drainage tube implants.International ophthalmology · 2018Article
Corrections and comments
- Updated by
Authors and funding
6 authors at 4 institutions in 1 country.
Funding
Abstract
backgroundAqueous shunts are employed for intraocular pressure (IOP) control in primary and secondary glaucomas that fail medical, laser, and other surgical therapies.
objectivesThis review compares aqueous shunts for IOP control and safety. SEARCH STRATEGY: We searched CENTRAL, MEDLINE, PubMed, EMBASE, NRR all in January 2006, LILACS to February 2004 and reference lists of included trials. SELECTION CRITERIA: We included all randomized and quasi-randomized trials in which one arm of the study involved shunts. DATA COLLECTION AND ANALYSIS: Two authors independently extracted data for included studies and a third adjudicated discrepancies. We contacted investigators for missing information. We used fixed-effect models and summarized continuous outcomes using mean differences. MAIN
resultsWe included fifteen trials with a total of 1153 participants with mixed diagnoses. Five studies reported details sufficient to verify the method of randomization but only two had adequate allocation concealment. Data collection and follow-up times were variable.Meta-analysis of two trials comparing Ahmed implant with trabeculectomy found trabeculectomy resulted in lower mean IOPs 11 to 13 months later (mean difference 3.81 mm Hg, 95% CI 1.94 to 5.69 mm Hg). Meta-analysis of two trials comparing double-plate Molteno implant with the Schocket shunt was not done due to substantial heterogeneity. One study comparing ridged with standard double-plate Molteno implants found no clinically significant differences in outcome. Two trials investigating the effectiveness of adjunctive mitomycin (MMC) with the Molteno and Ahmed implants found no evidence of benefit with MMC. Two trials that investigated surgical technique variations with the Ahmed found no benefit with partial tube ligation or excision of Tenon's capsule. One study concluded there were outcome advantages with a double versus a single-plate Molteno implant and one trial comparing the 350 mm(2) and 500 mm(2) Baerveldt shunts found no clinically significant advantage of the larger device but neither of these trials included all patients randomized. One study suggested improved clinical outcome when MMC was employed with a newly described shunt including ultrasound supporting the conclusion. One small study did not demonstrate an outcome advantage to systemic steroid use postoperatively with single-plate Molteno shunts. One study comparing endocyclophotocoagulation (ECP) with Ahmed implant in complicated glaucomas found no evidence of better IOP control with Ahmed implant over ECP. AUTHORS'
conclusionsRelatively few randomized trials have been published on aqueous shunts and methodology and data quality among them is poor. To date there is no evidence of superiority of one shunt over another.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.