Evidence map›Paper›PMID 16565065›Full record

ArticleBiophysical journal2006

In situ fluorescent protein imaging with metal film-enhanced total internal reflection microscopy.

Thomas P Burghardt, Jon E Charlesworth, Miriam F Halstead, James E Tarara, Katalin Ajtai

Open access · bronzeAbstract read
In one paragraph

Article in Biophysical journal, 2006. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed
6.0field-weighted citation impact, top 5% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed, 39 citations in OpenAlex.

  1. Surface plasmon-coupled emission imaging for biological applications.Analytical and bioanalytical chemistry · 2020
    Review
  2. Review
  3. Enhancing single molecule imaging in optofluidics and microfluidics.International journal of molecular sciences · 2011
    Review
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 1 country.

Thomas P BurghardtDepartment of Physiology and Biomedical Engineering, Mayo Clinic Rochester, Rochester, Minnesota 55905, USA. burghardt@mayo.edu
Jon E Charlesworth
Miriam F Halstead
James E Tarara
Katalin Ajtai
Mayo Clinic · USMayo Clinic in Florida · US

Funding

Visualizing Actomyosin Transients by Data MergingR01AR049277 · NIAMS · MAYO CLINIC ROCHESTER · PI BURGHARDT, THOMAS P · 2004 to 2013
$3.2M
NIAMS NIH HHS R01 AR049277NIAMS NIH HHS R01AR049277
6 · The paper itself

Abstract

Fluorescence detection of single molecules provides a means to investigate protein dynamics minus ambiguities introduced by ensemble averages of unsynchronized protein movement or of protein movement mimicking a local symmetry. For proteins in a biological assembly, taking advantage of the single molecule approach could require single protein isolation from within a high protein concentration milieu. Myosin cross-bridges in a muscle fiber are proteins attaining concentrations of approximately 120 muM, implying single myosin detection volume for this biological assembly is approximately 1 attoL (10(-18) L) provided that just 2% of the cross-bridges are fluorescently labeled. With total internal reflection microscopy (TIRM) an exponentially decaying electromagnetic field established on the surface of a glass-substrate/aqueous-sample interface defines a subdiffraction limit penetration depth into the sample that, when combined with confocal microscopy, permits image formation from approximately 3 attoL volumes. Demonstrated here is a variation of TIRM incorporating a nanometer scale metal film into the substrate/glass interface. Comparison of TIRM images from rhodamine-labeled cross-bridges in muscle fibers contacting simultaneously the bare glass and metal-coated interface show the metal film noticeably reduces both background fluorescence and the depth into the sample from which fluorescence is detected. High contrast metal film-enhanced TIRM images allow secondary label visualization in the muscle fibers, facilitating elucidation of Z-disk structure. Reduction of both background fluorescence and detection depth will enhance TIRM's usefulness for single molecule isolation within biological assemblies.

Indexed as

AluminumAnimalsCells, CulturedFluorescent DyesImage EnhancementMembranes, ArtificialMicroscopy, FluorescenceMuscle Fibers, SkeletalMyosinsRabbitsSarcomeresSpectrometry, FluorescenceStaining and LabelingAluminumFluorescent DyesMembranes, ArtificialMyosins

Identifiers

PMID16565065
PMCPMC1471853
OpenAlexW2083946654

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials