Evidence map›Paper›PMID 16547205›Full record

ArticleHeart (British Cardiac Society)2006

Prenatally diagnosed pulmonary atresia with ventricular septal defect: echocardiography, genetics, associated anomalies and outcome.

S Vesel, S Rollings, A Jones, N Callaghan, J Simpson, G K Sharland

Open access · bronzeAbstract read
In one paragraph

Article in Heart (British Cardiac Society), 2006. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
13citing papers in PubMed, 2 pooled it
2.0field-weighted citation impact, top 13% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

13 citing papers in PubMed, 2 syntheses or guidelines pooled it, 55 citations in OpenAlex.

  1. Pooled it
  2. Pooled it
  3. Review
  4. Review
  5. Review
  6. Article
  7. Article
  8. Article
  9. Prenatal diagnosis of tetralogy of Fallot with pulmonary atresia using: Fetal Intelligent Navigation Echocardiography (FINE).The journal of maternal-fetal & neonatal medicine : the official journal of the European Association of Perinatal Medicine, the Federation of Asia and Oceania Perinatal Societies, the International Society of Perinatal Obstetricians · 2019
    Article
  10. Article
  11. Article
  12. Article
  13. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 3 institutions in 2 countries.

S VeselUniversity Medical Centre, Department of Paediatrics, Cardiology Unit, Ljubljana, Slovenia.
S Rollings
A Jones
N Callaghan
J Simpson
G K Sharland
Guy's and St Thomas' NHS Foundation Trust · GBLjubljana University Medical Centre · SISt Thomas' Hospital · GB

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveTo assess the accuracy of prenatal diagnosis, the association with genetic and extracardiac anomalies, and outcome in fetuses with isolated pulmonary atresia with ventricular septal defect (PA-VSD). DESIGN AND

settingRetrospective study in a tertiary centre for fetal cardiology. PATIENTS AND OUTCOME MEASURES: Echocardiographic video recordings of 27 consecutive fetuses with PA-VSD were reviewed for: (1) intracardiac anatomy; (2) presence of confluence and size of the branch pulmonary arteries; (3) source of pulmonary blood supply; and (4) side of the aortic arch. Postmortem and postnatal data were added. Karyotyping was performed in 25 patients and, in 23 of these, fluorescent in situ hybridisation to identify 22q11.2 deletion.

resultsPA-VSD was correctly diagnosed in 19 of 21 patients (90%) with postnatal or autopsy confirmation of diagnosis. Central pulmonary arteries were correctly identified in 79% (15/19), the source of pulmonary blood supply in 62% (13/21) and major aortopulmonary collateral arteries in 44% (4/9). Aneuploidy was detected in 4 of 25 patients (16%) and 22q11.2 deletion in 6 of 23 patients (26%). Five of 27 patients (19%) had extracardiac anomalies. Eleven pregnancies were interrupted. Eleven of 16 liveborn babies survived. Neonatal survival was 15 of 16 (94%, 95% confidence interval (CI) 70 to 100), one-year survival was 9 of 12 (75%, 95% CI 43 to 95) and two-year survival was 5 of 9 (56%, 95% CI 21 to 86).

conclusionPA-VSD can be diagnosed by fetal echocardiography with a high degree of accuracy. However, it can be difficult to determine the morphology of the central pulmonary arteries and to locate the source of pulmonary blood supply. In most liveborn infants, complete surgical repair can be achieved.

Indexed as

EchocardiographyFemaleFetal DiseasesGestational AgeHeart Septal Defects, VentricularHumansPregnancyPregnancy OutcomePulmonary AtresiaRetrospective StudiesUltrasonography, Prenatal

Identifiers

PMID16547205
PMCPMC1861018
OpenAlexW2108704826

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.