Evidence map›Paper›PMID 16469130›Full record

ArticleCritical care (London, England)2006

Imposed work of breathing during high-frequency oscillatory ventilation: a bench study.

Marc van Heerde, Huib R van Genderingen, Tom Leenhoven, Karel Roubik, Frans B Plötz, Dick G Markhorst

Abstract read
In one paragraph

Article in Critical care (London, England), 2006. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed.

  1. Review
  2. Article
  3. Article
  4. Article
  5. Bias flow does not affect ventilation during high-frequency oscillatory ventilation in a pediatric animal model of acute lung injury.Pediatric critical care medicine : a journal of the Society of Critical Care Medicine and the World Federation of Pediatric Intensive and Critical Care Societies · 2012
    Article
  6. Article
  7. Article
  8. Year in review 2006: Critical Care--Respirology.Critical care (London, England) · 2007
    Review
  9. Article
  10. Review
  11. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Marc van HeerdeDepartment of Pediatric Intensive Care, VU University Medical Center, Amsterdam, The Netherlands. m.vanheerde@vumc.nl
Huib R van Genderingen
Tom Leenhoven
Karel Roubik
Frans B Plötz
Dick G Markhorst

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionThe ventilator and the endotracheal tube impose additional workload in mechanically ventilated patients breathing spontaneously. The total work of breathing (WOB) includes elastic and resistive work. In a bench test we assessed the imposed WOB using 3100 A/3100 B SensorMedics high-frequency oscillatory ventilators.

methodsA computer-controlled piston-driven test lung was used to simulate a spontaneously breathing patient. The test lung was connected to a high-frequency oscillatory ventilation (HFOV) ventilator by an endotracheal tube. The inspiratory and expiratory airway flows and pressures at various places were sampled. The spontaneous breath rate and volume, tube size and ventilator settings were simulated as representative of the newborn to adult range. The fresh gas flow rate was set at a low and a high level. The imposed WOB was calculated using the Campbell diagram.

resultsIn the simulations for newborns (assumed body weight 3.5 kg) and infants (assumed body weight 10 kg) the imposed WOB (mean +/- standard deviation) was 0.22 +/- 0.07 and 0.87 +/- 0.25 J/l, respectively. Comparison of the imposed WOB in low and high fresh gas flow rate measurements yielded values of 1.63 +/- 0.32 and 0.96 +/- 0.24 J/l (P = 0.01) in small children (assumed body weight 25 kg), of 1.81 +/- 0.30 and 1.10 +/- 0.27 J/l (P < 0.001) in large children (assumed body weight 40 kg), and of 1.95 +/- 0.31 and 1.12 +/- 0.34 J/l (P < 0.01) in adults (assumed body weight 70 kg). High peak inspiratory flow and low fresh gas flow rate significantly increased the imposed WOB. Mean airway pressure in the breathing circuit decreased dramatically during spontaneous breathing, most markedly at the low fresh gas flow rate. This led to ventilator shut-off when the inspiratory flow exceeded the fresh gas flow.

conclusionSpontaneous breathing during HFOV resulted in considerable imposed WOB in pediatric and adult simulations, explaining the discomfort seen in those patients breathing spontaneously during HFOV. The level of imposed WOB was lower in the newborn and infant simulations, explaining why these patients tolerate spontaneous breathing during HFOV well. A high fresh gas flow rate reduced the imposed WOB. These findings suggest the need for a demand flow system based on patient need allowing spontaneous breathing during HFOV.

Indexed as

Computer SimulationWork of BreathingHigh-Frequency VentilationResearch Design

Identifiers

PMID16469130
PMCPMC1550789

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.