Evidence map›Paper›PMID 16390971›Full record

ArticleJournal of clinical microbiology2006

Development and validation of a rotor-gene real-time PCR assay for detection, identification, and quantification of Chlamydia trachomatis in a single reaction.

Hamid Jalal, Hannah Stephen, Martin D Curran, Janet Burton, Michelle Bradley, Christopher Carne

Open access · greenAbstract readValidation Study
In one paragraph

Article in Journal of clinical microbiology, 2006. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 27 papers.

0numbers the graph read from it
0cells of the map it votes in
27citing papers in PubMed
1.9field-weighted citation impact, top 16% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

27 citing papers in PubMed, 59 citations in OpenAlex.

  1. Trachoma.Lancet (London, England) · 2025
    Review
  2. Article
  3. Molecular Detection ofJournal of arthropod-borne diseases · 2024
    Article
  4. Article
  5. Article
  6. One-step pentaplex real-time polymerase chain reaction assay for detection of zika, dengue, chikungunya, West nile viruses and a human housekeeping gene.Journal of clinical virology : the official publication of the Pan American Society for Clinical Virology · 2019
    Article
  7. Transcriptional Expression of theMicroorganisms · 2019
    Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Article
  17. Article
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Hamid JalalClinical Microbiology & Public Health Laboratory, Addenbrooke's Hospital, Cambridge, UK. hamid.jalal@addenbrookes.nhs.uk
Hannah Stephen
Martin D Curran
Janet Burton
Michelle Bradley
Christopher Carne
Addenbrooke's Hospital · GB

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

A multitarget real-time PCR (MRT-PCR) for detection of Chlamydia trachomatis DNA was developed and validated. There were three targets for amplification in a single reaction: the cryptic plasmid (CP), the major outer membrane protein (MOMP) gene, and an internal control. The assay had the following characteristics: (i) detection and confirmation of the presence of C. trachomatis DNA in a single reaction, (ii) detection of all genovars of C. trachomatis without any cross-reactivity with pathogenic bacteria or commensal organisms of the oropharynx and genital tract, (iii) a 95% probability of detection with three copies of MOMP and one copy of CP per reaction mixture, (iv) identification of the inhibition of amplification, (v) a quantitative dynamic range of 25 to 250,000 genome copies per reaction mixture, (vi) high intra- and interassay reproducibilities, and (vii) correct identification of all samples in the validation panel. There were 146 COBAS Amplicor PCR (Amplicor PCR)-positive samples and 122 Amplicor PCR-negative samples in the panel. MRT-PCR detected CP DNA alone in 6 (4%) Amplicor PCR-positive samples and both CP and MOMP DNAs in 140 (96%) of 146 Amplicor PCR-positive samples. The quantity of MOMP DNA in 95 (68%) of 140 samples was within the dynamic range of the assay. The median C. trachomatis load in these samples was 321 genome copies per reaction mixture (range, 26 to 40,137 genome copies per reaction mixture). Due to the inclusion of two different C. trachomatis-specific targets, the assay confirmed 259 (97%) of 268 results in a single reaction. This assay could be used in the qualitative format for the routine detection of C. trachomatis and in the quantitative format for study of the pathogenesis of C. trachomatis-associated diseases. The assay demonstrated the potential to eliminate the need for confirmatory testing in almost all samples, thus reducing the turnaround time and the workload.

Indexed as

Bacterial Outer Membrane ProteinsChlamydia InfectionsChlamydia trachomatisDNA, BacterialPolymerase Chain ReactionSensitivity and SpecificityBacterial Outer Membrane ProteinsDNA, Bacterial

Identifiers

PMID16390971
PMCPMC1351959
OpenAlexW2140769440

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.