Evidence map›Paper›PMID 16359559›Full record

ArticleBMC medical informatics and decision making2005

Design and implementation of GRIP: a computerized glucose control system at a surgical intensive care unit.

Mathijs Vogelzang, Felix Zijlstra, Maarten W N Nijsten

Registry-linked trialOpen access · goldAbstract read
In one paragraph

Article in BMC medical informatics and decision making, 2005. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT01085071 (GRIP-COMPASS Trial), which is not on this map. Cited by 48 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
48citing papers in PubMed, 2 pooled it
7.5field-weighted citation impact, top 2% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT01085071 phase4completednot on this mapstarted 2009, after this paper: background citation

GRIP-COMPASS Trial: Computer-driven Glucose and Potassium Regulation Program in Intensive Care Patients With COMparison of PotASSium Targets Within normokAlemic Range

TypeinterventionalSponsorUniversity Medical Center GroningenRan2009 to 2012Enrolled1,225ConditionsThoracic Surgery, Cardiac Surgery, Critically IllArmsPotassium Chloride
3 · Its place in the literature

Who cites it

48 citing papers in PubMed, 2 syntheses or guidelines pooled it, 145 citations in OpenAlex.

  1. Pooled it
  2. Pooled it
  3. Trial
  4. Trial
  5. Trial
  6. Trial
  7. Trial
  8. Trial
  9. Trial
  10. Trial
  11. Review
  12. Article
  13. Article
  14. Article
  15. Article
  16. Observational
  17. Review
  18. Article
  19. Article
  20. Glucose Control in the ICU: A Continuing Story.Journal of diabetes science and technology · 2016
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 2 institutions in 1 country.

Mathijs VogelzangDepartment of Surgery, Medical Center Groningen, University of Groningen, Groningen, The Netherlands. m.vogelzang@thorax.umcg.nl
Felix Zijlstra
Maarten W N Nijsten
University of Groningen · NLUniversity Medical Center Groningen · NL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundTight glucose control by intensive insulin therapy has become a key part of critical care and is an important field of study in acute coronary care. A balance has to be found between frequency of measurements and the risk of hypoglycemia. Current nurse-driven protocols are paper-based and, therefore, rely on simple rules. For safety and efficiency a computer decision support system that employs complex logic may be superior to paper protocols.

methodsWe designed and implemented GRIP, a stand-alone Java computer program. Our implementation of GRIP will be released as free software. Blood glucose values measured by a point-of-care analyzer were automatically retrieved from the central laboratory database. Additional clinical information was asked from the nurse and the program subsequently advised a new insulin pump rate and glucose sampling interval.

resultsImplementation of the computer program was uneventful and successful. GRIP treated 179 patients for a total of 957 patient-days. Severe hypoglycemia (< 2.2 mmol/L) only occurred once due to human error. With a median (IQR) of 4.9 (4.2-6.2) glucose measurements per day the median percentage of time in which glucose fell in the target range was 78%. Nurses rated the program as easy to work with and as an improvement over the preceding paper protocol. They reported no increase in time spent on glucose control.

conclusionA computer driven protocol is a safe and effective means of glucose control at a surgical ICU. Future improvements in the recommendation algorithm may further improve safety and efficiency.

Indexed as

Decision Support Systems, ClinicalIntensive Care UnitsPoint-of-Care SystemsAgedAlgorithmsAttitude of Health PersonnelAutoanalysisBlood GlucoseClinical ProtocolsCritical CareDrug Administration ScheduleFemaleHumansHypoglycemiaInsulinInsulin Infusion SystemsBlood GlucoseInsulin

Identifiers

PMID16359559
PMCPMC1334184
OpenAlexW2167650212

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.