SynthesisThe Cochrane database of systematic reviews2005
Gamma and other cephalocondylic intramedullary nails versus extramedullary implants for extracapsular hip fractures in adults.
Synthesis in The Cochrane database of systematic reviews, 2005. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 127 papers, 10 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
127 citing papers in PubMed, 10 syntheses or guidelines pooled it, 110 citations in OpenAlex.
- Extramedullary versus intramedullary fixation of unstable trochanteric femoral fractures (AO type 31-A2): a systematic review and meta-analysis.Archives of orthopaedic and trauma surgery · 2024Pooled it
- Extramedullary versus intramedullary fixation of stable trochanteric femoral fractures: a systematic review and meta-analysis.Archives of orthopaedic and trauma surgery · 2023Pooled it
- Cephalomedullary nails versus extramedullary implants for extracapsular hip fractures in older adults.The Cochrane database of systematic reviews · 2022Pooled it
- Internal fixation implants for intracapsular hip fractures in older adults.The Cochrane database of systematic reviews · 2021Pooled it
- Distal locked versus unlocked intramedullary nailing for stable intertrochanteric fractures, a systematic review and meta-analysis.BMC musculoskeletal disorders · 2020Pooled it
- Intramedullary versus extramedullary internal fixation for unstable intertrochanteric fracture, a meta-analysis.Acta orthopaedica et traumatologica turcica · 2018Pooled it
- Internal fixation treatments for intertrochanteric fracture: a systematic review and meta-analysis of randomized evidence.Scientific reports · 2015Pooled it
- Intramedullary nails for extracapsular hip fractures in adults.The Cochrane database of systematic reviews · 2014Pooled it
- Extramedullary fixation implants and external fixators for extracapsular hip fractures in adults.The Cochrane database of systematic reviews · 2013Pooled it
- Influence of osteoporosis on fracture fixation--a systematic literature review.Osteoporosis international : a journal established as result of cooperation between the European Foundation for Osteoporosis and the National Osteoporosis Foundation of the USA · 2008Pooled it
- Long-term home-based physical exercise, pain, and use of pain medication over a year after hip fracture - A secondary analysis of a randomised controlled trial.Clinical rehabilitation · 2026Trial
- Intramedullary Nailing vs Sliding Hip Screw in Trochanteric Fracture Management: The INSITE Randomized Clinical Trial.JAMA network open · 2023Trial
- Trial
- Effect on health-related quality of life of the X-Bolt dynamic plating system versus the sliding hip screw for the fixation of trochanteric fractures of the hip in adults: the WHiTE Four randomized clinical trial.The bone & joint journal · 2021Trial
- Fracture fixation in the operative management of hip fractures (FAITH): an international, multicentre, randomised controlled trial.Lancet (London, England) · 2017Trial
- Which implant is better for treating reverse obliquity fractures of the proximal femur: a standard or long nail?Clinical orthopaedics and related research · 2013Trial
- Is the lag screw sliding effective in the intramedullary nailing in A1 and A2 AO-OTA intertrochanteric fractures? A prospective study of Sliding and None-sliding lag screw in Gamma-III nail.Scandinavian journal of trauma, resuscitation and emergency medicine · 2012Trial
- Prospective randomised study comparing screw versus helical blade in the treatment of low-energy trochanteric fractures.International orthopaedics · 2011Trial
- Evaluation of Risk Factors for Revision Surgery After Proximal Femoral Nailing for Intertrochanteric Fractures.Medicina (Kaunas, Lithuania) · 2025Article
- [Comparison of Intramedullary Nails with Cephalic Screws and Dynamic Hip Screw in the Treatment of Unstable Intertrochanteric Fractures in Adults - A Systematic Review and Meta-Analysis].Revista brasileira de ortopedia · 2025Article
67 more citing papers are in PubMed but not listed here.
Corrections and comments
- Updated by
- Update of
Authors and funding
2 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundTwo types of implants used for the surgical fixation of extracapsular hip fractures are cephalocondylic intramedullary nails, which are inserted into the femoral canal proximally to distally across the fracture, and extramedullary implants.
objectivesTo compare cephalocondylic intramedullary nails with extramedullary implants (e.g. the sliding hip screw) for extracapsular hip fractures in adults. SEARCH STRATEGY: We searched the Cochrane Bone, Joint and Muscle Trauma Group Specialised Register (June 2005), the Cochrane Central Register of Controlled Trials, MEDLINE, EMBASE, the UK National Research Register, orthopaedic journals, conference proceedings and reference lists of articles. SELECTION CRITERIA: All randomised and quasi-randomised controlled trials comparing cephalocondylic nails with extramedullary implants for extracapsular hip fractures. DATA COLLECTION AND ANALYSIS: Both authors independently assessed trial quality and extracted data. Wherever appropriate, results were pooled. MAIN
resultsPredominantly older people with mainly trochanteric fractures were treated in the 32 included trials. Twenty trials, involving 3646 people, compared the Gamma nail with the sliding hip screw (SHS). The Gamma nail was associated with an increased risk of operative and later fracture of the femur and an increased reoperation rate. There were no major differences between implants in the wound infection, mortality or medical complications. Data were inadequate for other outcomes. Five trials, involving 623 people, compared the intramedullary hip screw (IMHS) with the SHS. Fracture fixation complications were more common in the IMHS group: all cases of operative and later fracture of the femur occurred in this group. Results for post-operative complications, mortality and functional outcomes were similar in the two groups. Two trials involving 314 people showed no difference in fracture fixation complications, reoperation, wound infection and length of hospital stay for proximal femoral nail (PFN) compared with the SHS. Single trial comparisons (experimental mini-invasive static intramedullary nail compared with the SHS: 60 participants; Kuntscher-Y nail with the SHS: 230 participants; Gamma nail and the Medoff sliding plate: 217 participants) failed to provide sufficient evidence to establish differences between implants in outcome. Two trials, involving 65 people with reverse and transverse fractures at the level of the lesser trochanter, found intramedullary nails (Gamma nail or PFN) were associated with better intra-operative results and fewer fracture fixation complications than extramedullary implants (a 90-degree blade plate or dynamic condylar plate) for these fractures. AUTHORS'
conclusionsGiven the lower complication rate of the SHS in comparison with intramedullary nails, SHS appears superior for trochanteric fractures. Further studies are required to determine if different types of intramedullary nail produce similar results, or if intramedullary nails have advantages for selected fracture types (for example, subtrochanteric fractures).
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.