Evidence map›Paper›PMID 16135767›Full record

ArticleThe Journal of neuroscience : the official journal of the Society for Neuroscience2005

Voltage-gated sodium channels improve contrast sensitivity of a retinal ganglion cell.

Narender K Dhingra, Michael A Freed, Robert G Smith

Open access · bronzeAbstract readComparative Study
In one paragraph

Article in The Journal of neuroscience : the official journal of the Society for Neuroscience, 2005. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
0.2field-weighted citation impact, top 55% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 14 citations in OpenAlex.

  1. Review
  2. Article
  3. NaV1.1 channels in axon initial segments of bipolar cells augment input to magnocellular visual pathways in the primate retina.The Journal of neuroscience : the official journal of the Society for Neuroscience · 2013
    Article
  4. Retinal pathway origins of the pattern electroretinogram (PERG).Investigative ophthalmology & visual science · 2011
    Article
  5. Article
  6. Article
  7. Ideal observer analysis of signal quality in retinal circuits.Progress in retinal and eye research · 2009
    Article
  8. Noise reduction of coincidence detector output by the inferior colliculus of the barn owl.The Journal of neuroscience : the official journal of the Society for Neuroscience · 2006
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 1 institution in 1 country.

Narender K DhingraDepartment of Neuroscience, University of Pennsylvania, Philadelphia, Pennsylvania 19104-6058, USA. naren@nbrc.ac.in
Michael A Freed
Robert G Smith
University of Pennsylvania · US

Funding

Scientific TransparencyP30EY001583 · NEI · UNIVERSITY OF PENNSYLVANIA · PI CLAIRE H MITCHELL · 1985 to 2026
$19.5M
MECHANISMS FOR TEMPORAL CODING BY RETINAL GANGLION CELLR01EY013333 · NEI · UNIVERSITY OF PENNSYLVANIA · PI FREED, MICHAEL A · 2001 to 2016
$4.6M
STRUCT/FUNCT OF RETINAL CIRCUIT FOR SCOTOPIC LUMINANCER01MH048168 · NIMH · UNIVERSITY OF PENNSYLVANIA · PI SMITH, ROBERT G · 1991 to 2004
$1.6M
NEI NIH HHS EY13333NEI NIH HHS P30 EY001583NEI NIH HHS R01 EY013333NIMH NIH HHS MH48168NIMH NIH HHS R01 MH048168
6 · The paper itself

Abstract

Voltage-gated channels in a retinal ganglion cell are necessary for spike generation. However, they also add noise to the graded potential and spike train of the ganglion cell, which may degrade its contrast sensitivity, and they may also amplify the graded potential signal. We studied the effect of blocking Na+ channels in a ganglion cell on its signal and noise amplitudes and its contrast sensitivity. A spot was flashed at 1-4 Hz over the receptive field center of a brisk transient ganglion cell in an intact mammalian retina maintained in vitro. We measured signal and noise amplitudes from its intracellularly recorded graded potential light response and measured its contrast detection thresholds with an "ideal observer." When Na+ channels in the ganglion cell were blocked with intracellular lidocaine N-ethyl bromide (QX-314), the signal-to-noise ratio (SNR) decreased (p < 0.05) at all tested contrasts (2-100%). Likewise, bath application of tetrodotoxin (TTX) reduced the SNR and contrast sensitivity but only at lower contrasts (< or = 50%), whereas at higher contrasts, it increased the SNR and sensitivity. The opposite effect of TTX at high contrasts suggested involvement of an inhibitory surround mechanism in the inner retina. To test this hypothesis, we blocked glycinergic and GABAergic inputs with strychnine and picrotoxin and found that TTX in this case had the same effect as QX-314: a reduction in the SNR at all contrasts. Noise analysis suggested that blocking Na+ channels with QX-314 or TTX attenuates the amplitude of quantal synaptic voltages. These results demonstrate that Na+ channels in a ganglion cell amplify the synaptic voltage, enhancing the SNR and contrast sensitivity.

Indexed as

Action PotentialsAnimalsContrast SensitivityGuinea PigsPhotic StimulationRetinal Ganglion CellsSodium ChannelsSodium Channels

Identifiers

PMID16135767
PMCPMC6725442
OpenAlexW2023013862

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.