Evidence map›Paper›PMID 16117553›Full record

ArticleJournal of the American Chemical Society2005

Angular-ratiometric plasmon-resonance based light scattering for bioaffinity sensing.

Kadir Aslan, Patrick Holley, Lydia Davies, Joseph R Lakowicz, Chris D Geddes

Open access · greenAbstract readComparative Study
In one paragraph

Article in Journal of the American Chemical Society, 2005. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 15 papers.

0numbers the graph read from it
0cells of the map it votes in
15citing papers in PubMed
6.4field-weighted citation impact, top 2% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

15 citing papers in PubMed, 91 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Review
  5. Article
  6. Article
  7. Article
  8. Article
  9. Review
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 1 country.

Kadir AslanInstitute of Fluorescence, Laboratory for Advanced Medical Plasmonics, Medical Biotechnology Center, University of Maryland Biotechnology Institute, 725 West Lombard Street, Baltimore, Maryland 21201, USA.
Patrick Holley
Lydia Davies
Joseph R Lakowicz
Chris D Geddes
Biotechnology Institute · USUniversity of Maryland, Baltimore · US

Funding

WHO'S WHO IN FLUORESCENCEP41RR008119 · NCRR · UNIVERSITY OF MARYLAND BALTIMORE · PI BASKAKOV, ILIA V · 1993 to 2006
$7.4M
Metal-Enhanced Fluorescence RNA SensingR21GM070929 · NIGMS · UNIVERSITY OF MD BIOTECHNOLOGY INSTITUTE · PI GEDDES, CHRISTOPHER DARREN · 2004 to 2005
$238k
NCRR NIH HHS P41 RR008119NCRR NIH HHS RR008119NIGMS NIH HHS GM070929NIGMS NIH HHS R21 GM070929
6 · The paper itself

Abstract

We describe an exciting opportunity for affinity biosensing using a ratiometric approach to the angular-dependent light scattering from bioactivated and subsequently aggregated noble metal colloids. This new model sensing platform utilizes the changes in particle scattering from very small colloids, which scatter light according to traditional Rayleigh theory, as compared to the changes in scattering observed by much larger colloidal aggregates, formed due to a bioaffinity reaction. These larger aggregates no longer scatter incident light in a Cos(2) theta dependence, as is the case for Rayleigh scattering, but instead scatter light in an increased forward direction as compared to the incident geometry. By subsequently taking the ratio of the scattered intensity at two angles, namely 90 degrees and 140 degrees , relative to the incident light, we can follow the association of biotinylated bovine serum albumin-coated 20 nm gold colloids, cross-linked by additions of streptavidin. This new model system can be potentially applied to many other nanoparticle assays and has many advantages over traditional fluorescence sensing and indeed light-scattering approaches. For example, a single nanoparticle can have the equivalent scattered intensity as 10(5) fluorescing fluorescein molecules substantially increasing detection; the angular distribution of scattered light from noble metal colloids is substantially easier to predict as compared to fluorescence; the scattered light is not quenched by biospecies; the ratiometric measurements described here are not dependent on colloid concentration as are other scattering techniques; and finally, the noble metal colloids are not prone to photodestruction, as is the case with organic fluorophores.

Indexed as

Biosensing TechniquesAffinity LabelsAvidinBiotinCoated Materials, BiocompatibleFluorescent DyesGold ColloidMetalsModels, ChemicalNanostructuresScattering, RadiationSerum Albumin, BovineStreptavidinSurface Plasmon ResonanceAffinity LabelsAvidinBiotinCoated Materials, BiocompatibleFluorescent DyesGold ColloidMetalsSerum Albumin, BovineStreptavidin

Identifiers

PMID16117553
PMCPMC6769416
OpenAlexW2067830052

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.