ArticleJournal of immunological methods2005
Myoglobin immunoassay based on metal particle-enhanced fluorescence.
Article in Journal of immunological methods, 2005. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 21 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
21 citing papers in PubMed, 84 citations in OpenAlex.
- SERS and SEF with enhancement in nanogaps: from fabrication to biosensing.Nanoscale advances · 2026Review
- Article
- Silver Nanoparticles Improve Fluorophore Photostability: Application to a Hypericin Study.International journal of molecular sciences · 2024Article
- Biosensing Platforms for Cardiac Biomarker Detection.ACS omega · 2024Review
- Plasmonic Fluorescence Enhancement in Diagnostics for Clinical Tests at Point-of-Care: A Review of Recent Technologies.Advanced materials (Deerfield Beach, Fla.) · 2023Review
- GLAD Based Advanced Nanostructures for Diversified Biosensing Applications: Recent Progress.Biosensors · 2022Review
- Fabrication and Characterization of Acute Myocardial Infarction Myoglobin Biomarker Based on Chromium-Doped Zinc Oxide Nanoparticles.Biosensors · 2022Article
- Review: Applications of surface-enhanced fluorescence (SEF) spectroscopy in bio-detection and biosensing.Sensing and Bio-Sensing Research · 2020Review
- Amplification of the signal intensity of fluorescence-based fiber-optic biosensors using a Fabry-Perot resonator structure.Sensors (Basel, Switzerland) · 2015Article
- No Added Value of Novel Biomarkers in the Diagnostic Assessment of Patients Suspected of Acute Coronary Syndrome.PloS one · 2015Article
- A straightforward immunoassay applicable to a wide range of antibodies based on surface enhanced fluorescence.Journal of fluorescence · 2013Article
- Immunoassays based on surface-enhanced fluorescence using gap-plasmon-tunable Ag bilayer nanoparticle films.Journal of fluorescence · 2013Article
- Plasmonic substrates for multiplexed protein microarrays with femtomolar sensitivity and broad dynamic range.Nature communications · 2011Article
- Quantitative Comparison of Protein Surface Coverage on Glass Slides and Silver Island Films in Metal-Enhanced Fluorescence-based Biosensing Applications.Nano biomedicine and engineering · 2010Article
- A microemulsion preparation of nanoparticles of europium in silica with luminescence enhancement using silver.Nanotechnology · 2009Article
- Near-infrared squaraine dyes for fluorescence enhanced surface assay.Dyes and pigments : an international journal · 2009Article
- Metal Enhanced Fluorescence on Silicon Wafer Substrates.Chemical physics letters · 2008Article
- Metal particle-enhanced fluorescent immunoassays on metal mirrors.Analytical biochemistry · 2007Article
- Microwave-Accelerated and Metal-Enhanced Fluorescence Myoglobin Detection on Silvered Surfaces: Potential Application to Myocardial Infarction Diagnosis.Plasmonics (Norwell, Mass.) · 2006Article
- Microwave-accelerated metal-enhanced fluorescence (MAMEF): application to ultra fast and sensitive clinical assays.Journal of fluorescence · 2006Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors at 1 institution in 1 country.
Funding
Abstract
Enhanced fluorescence on silver island films (SIFs) is utilized to develop a sandwich-format immunoassay for the cardiac marker myoglobin (Myo). Myoglobin was first captured on surfaces coated with anti-Myo antibodies; the surface was then incubated with fluorescently labeled anti-Myo antibodies. The system was examined on glass surfaces and on SIFs. We observed the enhancement of the signal from SIFs in the range of 10-15-fold if compared to the signal from the glass substrate not modified with a SIF. A kinetic immunoassay for Myo on SIF-modified surface results in a decreased background signal. The initial results show that it is possible to detect Myoglobin concentrations below 50 ng/mL, which is lower than clinical cut-off for Myoglobin in healthy patients. We suggest the use of SIF-modified substrates for increasing the sensitivity of surface assays with fluorescence detection.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.