Evidence map›Paper›PMID 15956387›Full record

ArticleJournal of clinical microbiology2005

Transfer and evaluation of an automated, low-cost real-time reverse transcription-PCR test for diagnosis and monitoring of human immunodeficiency virus type 1 infection in a West African resource-limited setting.

Francois Rouet, Didier K Ekouevi, Marie-Laure Chaix, Marianne Burgard, Andre Inwoley, Thomas D'Aquin Tony, Christine Danel, Xavier Anglaret, Valeriane Leroy, Philippe Msellati and 2 more

Abstract readEvaluation Study
In one paragraph

Article in Journal of clinical microbiology, 2005. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 94 papers.

0numbers the graph read from it
0cells of the map it votes in
94citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

94 citing papers in PubMed.

  1. Trial
  2. Trial
  3. Trial
  4. Trial
  5. Trial
  6. Trial
  7. Trial
  8. Trial
  9. Trial
  10. Trial
  11. Trial
  12. Trial
  13. Article
  14. Article
  15. The HIV-1Viruses · 2024
    Article
  16. Article
  17. Article
  18. Article
  19. Review
  20. Review

34 more citing papers are in PubMed but not listed here.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors.

Francois RouetCentre de Diagnostic et de Recherches sur le SIDA, Abidjan, Côte d'Ivoire. rouet@aviso.ci
Didier K Ekouevi
Marie-Laure Chaix
Marianne Burgard
Andre Inwoley
Thomas D'Aquin Tony
Christine Danel
Xavier Anglaret
Valeriane Leroy
Philippe Msellati
Francois Dabis
Christine Rouzioux

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

There is an urgent need for low-cost human immunodeficiency virus type 1 (HIV-1) viral load (VL) monitoring technologies in resource-limited settings. An automated TaqMan real-time reverse transcription-PCR (RT-PCR) assay was transferred to the laboratory of the Centre de Diagnostic et de Recherches sur le SIDA, Abidjan, Côte d'Ivoire, and assessed for HIV-1 RNA VL testing in 806 plasma samples collected within four ANRS research programs. The detection threshold and reproducibility of the assay were first determined. The quantitative results obtained with this assay were compared with two commercial HIV-1 RNA kits (the Versant version 3.0 and Monitor version 1.5 assays) in specimens harboring mainly the circulating recombinant form 02 strain (CRF02). The clinical evaluation of this test was done in different situations including the early diagnosis of pediatric infection and the monitoring of antiretroviral-treated patients. The quantification limit of our method was 300 copies/ml. The HIV-1 RNA values obtained by real-time PCR assay were highly correlated with those obtained by the Versant kit (r = 0.901; P < 0.001) and the Monitor test (r = 0.856; P < 0.001) and homogeneously distributed according to HIV-1 genotypes. For the early diagnosis of pediatric HIV-1 infection, the sensitivity and specificity of the real-time PCR assay were both 100% (95% confidence intervals of 93.7 to 100.0 and 98.3 to 100.0, respectively), compared to the Versant results. Following initiation of antiretroviral treatment, the kinetics of HIV-1 RNA levels were very comparable, with a similar proportion of adults and children below the detection limit during follow-up with our technique and the Versant assay. The TaqMan real-time PCR (12 dollars per test) is now routinely used to monitor HIV-1 infection in our laboratory. This technology should be further evaluated in limited-resource countries where strains other than CRF02 are prevalent.

Indexed as

Antiretroviral Therapy, Highly ActiveChildChild, PreschoolCote d'IvoireDeveloping CountriesHIV-1HIV InfectionsHumansReagent Kits, DiagnosticRecombination, GeneticReproducibility of ResultsReverse Transcriptase Polymerase Chain ReactionRNA, ViralSensitivity and SpecificityReagent Kits, DiagnosticRNA, Viral

Identifiers

PMID15956387
PMCPMC1151915

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.