Evidence map›Paper›PMID 15846656›Full record

SynthesisThe Cochrane database of systematic reviews2005

Laryngeal mask airway versus bag-mask ventilation or endotracheal intubation for neonatal resuscitation.

A J Grein, G M Weiner

Registry-linked trialAbstract readSystematic Review
PubMed Publisher
In one paragraph

Synthesis in The Cochrane database of systematic reviews, 2005. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT02042118 (Randomized Clinical Trial Assessing Laryngeal Mask Airway), which is not on this map. Cited by 12 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
12citing papers in PubMed, 1 pooled it
2.9field-weighted citation impact, top 12% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT02042118 nacompletednot on this mapstarted 2014, after this paper: background citation

Randomized Clinical Trial Assessing Laryngeal Mask Airway (LMA) Versus Face-mask Ventilation (FMV) in Neonatal Resuscitation at Mulago Hospital, Uganda

TypeinterventionalSponsorCentre For International HealthRan2014 to 2016Enrolled50ConditionsAsphyxia NeonatorumArmsLaryngeal Mask Airway, Face mask ventilation
3 · Its place in the literature

Who cites it

12 citing papers in PubMed, 1 synthesis or guideline pooled it, 74 citations in OpenAlex.

  1. Pooled it
  2. Trial
  3. Trial
  4. Article
  5. Article
  6. Review
  7. Article
  8. Article
  9. Review
  10. Article
  11. Article
  12. Review
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

2 authors at 1 institution in 1 country.

A J GreinDepartment of Pediatrics, Neonatal-Perinatal Medicine, Indiana University School of Medicine, USA, 699 West Drive, RR 208, James Whitcomb Riley Hospital for Children, Indianapolis, Indiana 46202-5119, USA. ajgrein@iupui.edu
G M Weiner
Riley Hospital for Children · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundProviding effective positive pressure ventilation is the single most important component of successful neonatal resuscitation. Ventilation is frequently initiated with a manual resuscitation bag and face-mask (BMV) followed by endotracheal intubation (ETT) if depression continues. These techniques may be difficult to perform successfully resulting in prolonged resuscitation or severe neonatal depression. The laryngeal mask airway (LMA) may achieve initial ventilation and successful resuscitation faster than a bag-mask device or endotracheal intubation.

objectivesAmong newborns requiring positive pressure ventilation for resuscitation, is effective ventilation and successful resuscitation achieved faster with the LMA compared with either BMV or ETT? SEARCH STRATEGY: The Cochrane Central Register of Controlled Trials (CENTRAL, The Cochrane Library, Issue 3, 2004), MEDLINE (1966-November 2004), Pre-MEDLINE (November 15, 2004), CINAHL 1982-November 2004), reference lists of published trials, and Society for Pediatric Research abstracts were searched. Experts were contacted for additional references. SELECTION CRITERIA: Randomised and quasi-randomised trials DATA COLLECTION AND ANALYSIS: Two reviewers independently evaluated studies, assessed methodologic quality, and extracted data using the Cochrane Neonatal Review Group criteria. Categorical treatment effects were described as relative risks and risk differences and continuous treatment effects were described as the mean difference. There were insufficient data to perform pooled analyses. MAIN

resultsNo eligible studies compared the LMA with BMV. One small randomised controlled trial comparing the LMA with ETT when BMV had been unsuccessful was included. There was no statistically significant difference between the LMA and ETT with the exception of a clinically insignificant difference in time to complete insertion of the device favouring the ETT. AUTHORS'

conclusionsThe LMA can achieve effective ventilation during neonatal resuscitation in a time-frame consistent with current guidelines. There is no evidence to evaluate the relative efficacy and safety of the LMA compared with BMV as the primary airway device. A single, small randomised controlled trial found no clinically significant difference between the LMA and ETT when BMV was unsuccessful. Case series and case reports suggest that the LMA can provide an effective rescue airway during resuscitation if both BMV and ETT have been unsuccessful. A well-designed randomised controlled trial comparing the LMA with BMV during neonatal resuscitation is warranted.

Indexed as

Laryngeal MasksHumansInfant, NewbornIntubation, IntratrachealPositive-Pressure RespirationRandomized Controlled Trials as TopicResuscitation

Identifiers

PMID15846656
OpenAlexW1540524690

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.